Whole-home inspection, 83 Grand Circle Drive, Maryland Heights, MO 63043
Greensmith Home Inspection LLC documented home inspection work at 83 Grand Circle Drive, Maryland Heights, MO 63043 on June 17, 2026. Average radon level measured at 0.5 pCi/L, well below the EPA action level of 4.0 pCi/L.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of 83 Grand Circle Dr, Maryland Heights, MO 63043 identified multiple deficiencies including an inoperable attic fan, power line hazard, sewer blockage, broken water shutoff handle, failed laundry GFCI outlet, and a basement window locking issue; home is generally in good condition with no structural issues.
- RadonRadon test conducted in basement from June 17. average radon level measured at 0.5 pCi/L, well below the EPA action level of 4.0 pCi/L
- PestWood Destroying Insect inspection of SFR/Attached Garage found no visible evidence of wood destroying insects; no action or treatment recommended.
- SewerSewer camera inspection of main line (3-inch PVC to 4-inch cast iron to 6-inch clay tile to yard vent) revealed the line holding water and a blockage the camera could not pass, with a suspected break in the clay tile located and marked with green paint approximately 5 ft. deep in the back yard; report recommended to be submitted to the lateral sewer program for repair and reinspection.
- ElectricalTree limbs are pushing overhead power lines down to approximately 9 feet from the ground and need to be cut back by Ameren; Siemens 200-amp service panel is newer and appears functional.
- FoundationPoured concrete basement foundation is in satisfactory condition with no moisture intrusion detected; one basement wall crack needs to be sealed with urethane.
- HVACAttic fan is inoperable from the wall switch and needs repaired or replaced; Goodman forced-air furnace (Mfgd 2024, 80,000 BTU) and Ameristar 2.5-ton condenser (Mfgd 2018) are functioning but require cleaning, servicing, and a missing HVAC filter needs to be replaced.
- PestVisual inspection of the site revealed no termite or pest presence or damage observed.
- PlumbingBroken handle on the main water shutoff valve in the basement needs replacement; Bradford White 40-gallon electric water heater (Mfgd 2025) is functioning properly; basement laundry GFCI outlet is older, will not reset, and needs replaced.
- RoofArchitectural shingle roof estimated 10 years old is installed correctly and in satisfactory condition; metal gutters contain leaves and need cleaning.
- SewerSewer lateral videoscope revealed a complete blockage at the sinkhole in the backyard; the line is suspected to be collapsed and St. Louis MSD Sewer is recommended to inspect, as it may be covered under the city's program.
- WindowsNewer double-hung vinyl windows open and close properly; however, one basement window will not lock and needs an adjustment to the locking mechanism.
- HVACGas appliance inspection of 2024 80k BTU 80% efficiency furnace (passed combustion analysis, dirty condition), 2018 2.5-ton condenser (dirty, not cooling properly, refrigerant charge appears low), 2017 3-ton A-coil (properly draining), and ductwork (serviceable); gas lines hold pressure with no major concerns noted.
83 Grand Circle Drive
Maryland Heights, Missouri
Whole-home inspection, 416 Harvest Hill Court, Ballwin, MO 63021
Greensmith Home Inspection LLC documented home inspection work at 416 Harvest Hill Court, Ballwin, MO 63021 on June 16, 2026. Radon test conducted in the basement from June 16–18, 2026 using a RadStar RS300 monitor.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of 416 Harvest Hill Ct, Ballwin, MO 63021 identified multiple deficiencies including elevated CO levels from the HVAC system, outdated GFCI outlets, a leaky laundry drain pipe, a bad tub diverter, dry-rotted exterior door trim, and a dirty gas fireplace requiring professional cleaning.
- RadonRadon test conducted in the basement from June 16; 18, 2026 using a RadStar RS300 monitor; average radon level measured at 0.5 pCi/L (maximum 1.5 pCi/L, minimum 0.1 pCi/L), which is below the EPA action level of 4.0 pCi/L.
- PestWood Destroying Insect inspection of SFR/Attached Garage at 416 Harvest Hill Court, Ballwin, MO: no visible evidence of wood destroying insects was observed; no action or treatment recommended.
- SewerCamera inspection of main sewer line from 4-inch PVC to 6-inch PVC to the MSD tie-in; line is open and flowing and looks good.
- ElectricalGFCI outlets in both the master bathroom and hallway bathroom are outdated and will not reset, requiring repair or replacement; one basement outlet has an open ground wire needing repair; master bathroom exhaust fan is extremely loud with a likely failing bearing and should be replaced.
- FoundationPoured concrete basement foundation is in satisfactory condition with no structural issues observed; common cracks in the unfinished basement floor are noted and should be sealed with urethane caulk.
- HVACCombustion analyzer test failed with CO levels higher than industry standards on the 2021 Emerald furnace; qualified HVAC contractor evaluation and readjustment recommended; fireplace gas logs are dirty with carbon buildup and need professional cleaning.
- PlumbingLeaky drain pipe found at the basement laundry sink; hallway bathroom tub faucet diverter is likely bad (approximately 50% of water dumps from tub spout in shower mode) and faucet handle is not attached; water heater (AO Smith, 50-gal, natural gas, Mfgd 2021) is functioning properly.
- RoofArchitectural shingle roof estimated 8; 10 years old is installed correctly and in satisfactory condition; skylight repairs appear effective; porch is missing a trim piece of fascia with exposed wood present.
- WindowsVinyl windows throughout are in satisfactory condition; caulking around window interiors is recommended as needed.
- HVACGas appliance inspection identified: furnace combustion analyzer test failed with CO levels above industry standards and abnormal blower/inducer motor noise; flue too close to combustible material; water heater and furnace gas shut-off valves not hand-turnable; copper gas lines not marked; gas shut-off valve not labeled; stove middle burner did not light completely; gas log dirty with carbon buildup; condenser not properly secured to rack and condenser fins dirty; qualified HVAC contractor evaluations and repairs recommended for all items.

416 Harvest Hill Court
Ballwin, MO
Whole-home inspection, 505 Ridge Drive, Florissant, MO 63033
Greensmith Home Inspection LLC documented home inspection work at 505 Ridge Drive, Florissant, MO 63033 on February 25, 2026. GFCI outlet at rear patio is older and will not reset and needs replacement.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property identified multiple deficiencies including a gas-company-flagged range, blocked sewer lateral, excessively rusted 2002 water heater, and a hole in the roof over the garage; no structural deficiencies observed.
- ElectricalGFCI outlet at rear patio is older and will not reset and needs replacement; loose outlet noted in dining room; 2-prong ungrounded outlets present throughout; Murray 200-amp service panel in garage appears functional.
- FoundationSlab-on-grade poured concrete foundation and wood-frame wall structure both observed in satisfactory condition with no structural deficiencies noted.
- HVACGoodman central split system (2.5-ton A/C, forced-air furnace) manufactured in 2017 appears satisfactory; furnace could not be tested due to gas shutoff; missing drum panel cover noted; gas kitchen range (Amana) flagged by gas company for inoperable igniter.
- PlumbingKenmore gas water heater manufactured in 2002 is excessively rusted and needs replacement; copper supply pipes satisfactory; property is winterized with no water service active at time of inspection.
- RoofArchitectural shingle roof estimated 10; 15 years old with a hole in the roof over the attached garage requiring repair; remaining shingles are performing properly.
- SewerSewer lateral videoscope performed; buildup and debris have reduced the interior diameter to the point where the camera could not reach the city main; sewer lines need to be cabled/cleared then re-camera'd.

505 Ridge Drive
Florissant, MO
Whole-home inspection, 225 Sadonia Avenue, Ferguson, MO 63135
Greensmith Home Inspection LLC documented home inspection work at 225 Sadonia Avenue, Ferguson, MO 63135 on February 25, 2026. Damaged electrical meter box needs replacement.
Some source files are restricted or not yet available; only cleared records are shown.
- ElectricalDamaged electrical meter box needs replacement; a loose live wire hanging from the basement ceiling needs to be capped immediately; 2-prong ungrounded outlets are present throughout the home.
- FoundationBasement moisture condition is damp due to cut plumbing supply lines dripping at the water meter; basement walls show damage from moisture and require repair.
- HVACHVAC furnace is estimated 40; 50 years old (Space Conditioner, evap lines cut) and the Comfortmaker AC compressor was manufactured in 1992; the entire HVAC system needs replacement.
- MoldA steady drip from cut copper supply lines has pooled onto the basement floor, resulting in mildew growth on wood paneling and mold-like growth observed on basement walls.
- PlumbingCopper plumbing supply lines have been cut and need full replacement; gas water heater (Hotpoint, 40 gal, manufactured 2011) is present with satisfactory T&P relief valve.
- RoofArchitectural shingle roof is estimated 5 years old and performing; tree limbs should be cut back from the roof, missing soffit panels need replacement, and loose soffit panels need to be secured.
- SewerSewer lateral videoscope was performed to the home; no pipe damages were observed, however a blockage is present that needs cleared and buildup needs cabled/removed.
- WindowsOne broken window pane on the corner bedroom needs replacement.
225 Sadonia Avenue
Ferguson, MO
Whole-home inspection, 6317 Jackson Avenue, Berkeley, MO 63134
Greensmith Home Inspection LLC documented home inspection work at 6317 Jackson Avenue, Berkeley, MO 63134 on August 9, 2024. Smoke detectors are missing/non-operational throughout the home.
Some source files are restricted or not yet available; only cleared records are shown.
- Home Inspectionno structural deficiencies were observed
- ElectricalSmoke detectors are missing/non-operational throughout the home; bathroom GFCI outlet is older and will not reset and needs replacement; kitchen GFCI outlet has a broken ground prong that needs removal; most interior outlets are two-prong ungrounded.
- FoundationConcrete floor in the rear utility room is severely bowed, though it does not appear to affect the structure; poured concrete foundation is otherwise satisfactory.
- HVACAC condenser lines (2.5-ton Goodman, mfgd 2020) have been cut from the system and need replacement; Whirlpool gas furnace (mfgd 2016) needs cleaning and servicing, and vegetation must be cleared from the condenser.
- PlumbingCopper supply plumbing lines have been cut and removed from the home and need to be replaced; water heater T&P relief valve discharge pipe also needs replacement.
- RoofTree limbs are contacting the roof structure and need to be cut back; a large roof vent over the rear porch is leaning and needs to be straightened; 3-tab shingle roof covering is estimated 15 years old and in satisfactory condition.
- WindowsOne broken window needs replacement and caulking is needed around windows throughout the exterior.

6317 Jackson Avenue
Berkeley, MO
Whole-home inspection, 1890 Pyrenees Drive, Florissant, MO 63033
Greensmith Home Inspection LLC documented home inspection work at 1890 Pyrenees Drive, Florissant, MO 63033 on November 16, 2023. Murray 100-amp service panel located in the basement is a newer panel approved by the City of Florissant (electrical inspection dated 5-3-19).
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of 1890 Pyrenees Dr, Florissant, MO found the home in generally good shape with no structural deficiencies; key concerns include a heavy plumbing leak below the kitchen, cracking basement wall repairs, and a 20-year-old HVAC system needing service.
- ElectricalMurray 100-amp service panel located in the basement is a newer panel approved by the City of Florissant (electrical inspection dated 5-3-19); overcurrent protection via breakers is satisfactory and no outlet defects were noted.
- FoundationPrevious repairs to the basement wall are beginning to crack; inspector recommends tearing out old fill and sealing the crack with epoxy injection; no active moisture intrusion was observed but signs of previous moisture were present.
- HVACBryant forced-air gas furnace (71,000 BTU, manufactured 2001) and Bryant 2.5-ton split-system condenser (manufactured 2001) are approximately 20 years old, need cleaning and servicing, but appear to be performing.
- PestNo termite or pest presence or damage was observed at the time of inspection.
- PlumbingA massive leak is present directly below the kitchen from a loose fitting in the supply lines; the main water shut off valve is also leaking at the handle and needs repair; the 40-gallon State natural gas water heater (manufactured 2020) appears functional.
- RoofThree-tab shingled roof estimated 10; 15 years old is in satisfactory condition; 1; 2 shingles are lifted and need to be sealed down, and tree limbs overhanging the roof should be cut back as a large limb has dropped onto the power lines.
- WindowsExterior windows consist of wood, vinyl, and steel-framed basement windows, all observed in satisfactory condition.

1890 Pyrenees Drive
Florissant, Missouri
Whole-home inspection, 11830 Seven Hills Drive, Florissant, MO 63033
Greensmith Home Inspection LLC documented home inspection work at 11830 Seven Hills Drive, Florissant, MO 63033 on November 16, 2023. Newer Eaton 100-amp service panel with breakers is satisfactory.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property identified a major plumbing leak, rotted rear deck decking, damaged rear patio door, older termite damage to fence, 3 missing/inoperable smoke detectors, sunk front walkway, and various maintenance items; no structural deficiencies observed.
- ElectricalNewer Eaton 100-amp service panel with breakers is satisfactory; 3 inoperable/missing smoke detectors need replacement; electric outlets could not be tested due to no power during inspection.
- FoundationPoured concrete basement foundation is in satisfactory condition with no moisture detected; a previous exterior foundation repair appears to be effective.
- HVACGoodman central split system (forced air gas heat, 3-ton electric cooling condenser) manufactured in 2016 appears functional; digital thermostat in hallway; metal ducting and disposable filter in satisfactory condition.
- PestOlder termite damage is present to the wood fence; no damage was observed to the structure; spraying for termites/wood-destroying insects every 3; 5 years is recommended.
- PlumbingMassive water leak present at the regulator valve under the kitchen sink; water ran full strength across the kitchen floor, requiring water service to be shut off; plumbing could not be fully tested; water heater is a Rheem 40-gallon natural gas unit manufactured in 2014, appears functional.
- Roof3-tab shingle gable roof estimated 15 years old is in satisfactory condition; tree limbs are hanging over the roof and need to be cut back; gutters contain leaves and debris that need to be removed.
- WindowsExterior windows are vinyl, steel-framed basement windows, and glass block, all in satisfactory condition.

11830 Seven Hills Drive
Florissant, MO
Whole-home inspection, 2221 Kipp Court, St. Louis, MO 63136
Greensmith Home Inspection LLC documented home inspection work at 2221 Kipp Court, St. Louis, MO 63136 on November 14, 2023. Exterior outlet at rear patio is loose from the wall and needs secured.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property at 2221 Kipp Ct identified multiple repair items including missing copper plumbing lines, spot mold in basement, a non-functional GFCI outlet, loose exterior electrical outlet, missing thermostat faceplate, tree limbs contacting the roof, and a detached rear gutter, with no structural deficiencies observed.
- ElectricalExterior outlet at rear patio is loose from the wall and needs secured; GFI outlet in master bathroom will not reset and needs replaced; 100-amp Square D service panel with breakers appears functional.
- FoundationPoured concrete basement foundation is satisfactory with no structural deficiencies; prior repairs to the basement wall appear effective; basement moisture condition is wet due to a cut water line causing pooled water on the floor.
- HVACGoodman central split system (manufactured 2013) with forced air heating and 2.5-ton condenser appears functional, but the thermostat faceplate has been removed and needs replaced; system is over 10 years old and should be serviced yearly.
- MoldA water line has been cut and water has pooled on the basement floor, resulting in spot mold; after replacing the missing pipe, pooled water and mold must be cleaned up and removed.
- PestNo termite or pest presence/damage was observed at the property.
- PlumbingCopper supply plumbing lines have been cut and a good amount of plumbing line is missing and will need replaced; the copper discharge pipe on the water heater has been removed and needs replaced; the water meter handle is seized shut and needs lubricated; master bathroom tub requires caulking and a missing handle replacement.
- RoofArchitectural shingle roof (estimated 5 years old) is satisfactory overall, but tree limbs are hanging over and contacting the roof, the gutter over the rear patio is pulling away from the home and needs realigned, and loose soffit needs to be secured.
- WindowsVinyl and aluminum exterior windows are in satisfactory condition; trim around the front living room window needs to be reinstalled.
2221 Kipp Court
St. Louis, MO
Whole-home inspection, 12721 Coachlight Square Drive, Florissant, MO 63033
Greensmith Home Inspection LLC documented home inspection work at 12721 Coachlight Square Drive, Florissant, MO 63033 on November 14, 2023. Loose electrical outlet at front porch needs to be secured.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property at 12721 Coachlight Square Dr, Florissant, MO 63033 identified mold in basement, active plumbing leak, HVAC rust damage, missing smoke detectors, and roof/exterior deficiencies; no structural deficiencies observed.
- ElectricalLoose electrical outlet at front porch needs to be secured; smoke detectors are not present throughout the home and functional units need to be installed.
- FoundationPoured concrete basement foundation is satisfactory with no structural deficiencies observed; previous home-made repairs are present on basement walls and appear to be effective.
- HVAC2010 York gas furnace in basement has excessive rust due to proximity to a leaking bathroom drain pipe, loose chipboard needs securing, and furnace needs cleaning and servicing by an HVAC technician; 2011 York 2.5-ton AC compressor appears functional.
- MoldMost basement sheetrock has a fine coat of mildew turning into mold caused by a plumbing leak in the master bathroom; after the plumbing leak is repaired, moldy sheetrock needs to be removed and replaced.
- PestNo termite or pest presence or damage was observed at the property.
- PlumbingDrain line for master bathroom toilet is leaking onto the basement floor; hallway bathroom vanity sink is missing a drain nozzle; pressure regulator needs installation or adjustment due to very low water pressure throughout; Rheem tankless water heater (manufactured 2014) has no temperature and pressure relief valve present.
- RoofThree-tab shingled roof is performing with shingles estimated at 15 years old; one damaged shingle on the front corner needs replacement, tree limbs need to be cut back from the roof, and minor fascia board damage on the south side needs repair.

12721 Coachlight Square Drive
Florissant, Missouri
Whole-home inspection, 11632 Criterion Avenue, St. Louis, MO 63138
Greensmith Home Inspection LLC documented home inspection work at 11632 Criterion Avenue, St. Louis, MO 63138 on November 10, 2023. Tree limbs are pushing on overhead power lines and Ameren should be contacted to trim them.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property at 11632 Criterion Ave., St. Louis, MO 63138 identified multiple defects across plumbing, electrical, roofing, and other systems; no structural deficiencies were observed.
- ElectricalTree limbs are pushing on overhead power lines and Ameren should be contacted to trim them; kitchen GFI outlet will not reset and needs replacement; one inoperable smoke detector in the basement needs replacement.
- FoundationPoured concrete foundation is in satisfactory condition; an exterior foundation crack has been repaired with urethane caulk and no moisture intrusion was observed.
- HVACGoodman gas forced-air furnace (2013, 80,000 BTU) and DuCane central split-system condenser (2013, 2.5-ton) are both functioning with no deficiencies observed; disposable filter replacement is suggested.
- PestNo termite damage or pest presence was observed at the property; termite treatment appears to have been previously performed.
- PlumbingExterior faucet is seized shut and needs replacement; hallway bathroom tub faucet turns on but will not turn off and has worn the tub finish, requiring faucet replacement and tub finish repair; hallway toilet will not flush as the handle is not connected to the flange valve.
- Roof3-tab shingle roof estimated at 10 years old is performing satisfactorily; missing soffit panels need replacement, front guttering is loose and needs securing, and a missing downspout piece at the front corner needs replacement.
- SewerSewer lateral videoscope was performed and revealed no structural damage or obstructions, but tree roots are intruding into the lines and buildup/scaling is present; technician recommends cabling/clearing the lines.
- WindowsWindows (vinyl, aluminum, and steel-framed basement windows) are in satisfactory condition overall, but caulking/sealing around windows is needed where gaps are present.
11632 Criterion Avenue
St. Louis, Missouri
Whole-home inspection, 11620 Petite Chalet Drive, St. Louis, MO 63138
Greensmith Home Inspection LLC documented home inspection work at 11620 Petite Chalet Drive, St. Louis, MO 63138 on November 10, 2023. Smoke detectors are inoperable or not present throughout the home and need to be installed.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property identified multiple defects across roofing, foundation, plumbing, electrical, HVAC, windows, and interior systems requiring repair or further evaluation.
- ElectricalSmoke detectors are inoperable or not present throughout the home and need to be installed; GFI outlet to the left of the kitchen sink will not reset and needs replaced.
- FoundationConcrete foundation appears in good shape overall, but small exterior cracks are present that need repaired with epoxy injection; basement moisture condition is wet due to a leaking laundry faucet bib.
- HVACGoodman central split system furnace and AC compressor (both manufactured 2014) need cleaned and serviced by an HVAC technician; hallway bathroom ventilator is inoperable and needs repaired or replaced.
- PlumbingLaundry faucet bib is leaking onto the basement floor with pooled water, hallway bathroom tub would not shut off, master bathroom toilet will not flush, and the water heater TPR valve needs a discharge pipe installed.
- RoofThree tab shingles estimated 7-10 years old are generally satisfactory, but three shingles are damaged and need replaced, tree limbs need cut back from the roof, and gutters need leaves and debris removed.
- WindowsDamaged wood around the front window needs to be replaced.
- UnclassifiedFront porch has a very large crack that needs sealed; missing exterior trim panel at front corner exposes wood framing; garage door opener pulled off track needs reset; kitchen cabinets need secured to the wall; dishwasher is inoperable and needs repaired or replaced; ceiling damage over rear patio door needs repair.
11620 Petite Chalet Drive
St. Louis, MO
Whole-home inspection, 8504 Jacklin Court, Hazelwood, MO 63042
Greensmith Home Inspection LLC documented home inspection work at 8504 Jacklin Court, Hazelwood, MO 63042 on November 8, 2023. Smoke detectors tested satisfactory.
Some source files are restricted or not yet available; only cleared records are shown.
- Electricalsmoke detectors tested satisfactory. no defects noted in interior outlets
- FoundationPoured concrete basement foundation is in satisfactory condition with no deficiencies observed in walls; basement moisture condition was wet at time of inspection due to water heater tank being drained onto the floor; no perimeter insulation visible.
- HVACdigital thermostat has dead batteries
- PestNo termite or pest presence or damage was observed at the property.
- PlumbingWater heater (State brand, 40-gallon natural gas, manufactured 2009) had its drain opened by an unknown person prior to inspection, causing water to pool on the basement floor; water service was shut off to the home at time of inspection; copper supply pipes and PVC waste pipes are satisfactory.
- RoofArchitectural shingle roof estimated 10 years old is in satisfactory condition; soffit has been removed and some roof decking was burned on the rear corner requiring repair; gutters are clogged with leaves and debris and need clearing; tree limbs overhang the roof and should be cut back.
- WindowsTwo broken glass window panes were observed and require replacement.

8504 Jacklin Court
Hazelwood, MO
Whole-home inspection, 832 Briarbrae Drive, St. Louis, MO 63138
Greensmith Home Inspection LLC documented home inspection work at 832 Briarbrae Drive, St. Louis, MO 63138 on November 8, 2023. Electric panel is a recalled Zinsco old-style unit that needs replaced.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property at 832 Briarbrae Dr, St Louis, MO 63138 identified multiple deficiencies including a recalled electrical panel, mold in the basement, termite damage, damaged windows, aging water heater, and extensive interior drywall damage requiring repair or replacement.
- ElectricalElectric panel is a recalled Zinsco old-style unit that needs replaced; 2 loose exterior electrical outlets on north and rear sides of home need secured; no functioning smoke detectors are present and need installed throughout the home.
- FoundationPoured concrete foundation is in satisfactory condition overall; a crack in the rear corner foundation needs to be contained with urethane caulk.
- HVACGoodman AC and furnace manufactured in 2014 appears functional but is dirty and needs cleaned and serviced by an HVAC technician; HVAC filter has been jammed into the slot and needs replaced.
- MoldSigns of previous moisture and slight mold are present on sheetrock walls in one basement room; moldy sheetrock panels need torn out and replaced, and any cracks in the concrete wall behind the sheetrock need sealed.
- PestOlder termite damage is present on wood shake siding and porch posts; termite treatment has been performed to the structure, and spraying the exterior every 3-5 years for termites/wood destroying insects is recommended.
- PlumbingRichmond gas water heater manufactured in 1997 is approaching end of expected life, appears to have been leaking, and likely needs replaced; PEX supply lines appear recently installed and are in satisfactory condition.
- RoofArchitectural shingles are estimated 8-10 years old and in generally good shape, but a few shingles above the front porch have crumpled and need sealed and pressed down; rear corner gutter has fallen off the home and needs reset.
- WindowsTwo glass windows and one glass door need replaced due to breakage; overall window condition is noted as repairs needed.
832 Briarbrae Drive
St. Louis, MO
Whole-home inspection, 12030 Lavida Avenue, St. Louis, MO 63138
Greensmith Home Inspection LLC documented home inspection work at 12030 Lavida Avenue, St. Louis, MO 63138 on August 24, 2023. Smoke detectors are missing and need replacement.
Some source files are restricted or not yet available; only cleared records are shown.
- Electricalsmoke detectors are missing and need replacement. exterior carport outlet needs a new weatherproof cover. tree limbs are pushing on overhead power lines
- FoundationPoured concrete basement foundation is satisfactory with no structural deficiency; small exterior cracks noted and should be sealed with urethane caulk; basement has a musty smell with signs of previous moisture intrusion, attributed in part to a leaky kitchen sink draining onto the basement bathroom ceiling.
- HVACthermostat batteries are dead and need replacement
- PestOlder termite damage is present on the wood fence with no active presence observed on the structure; termite/wood-destroying insect treatment is recommended every 3-5 years.
- PlumbingSigns of a plumbing leak under the kitchen sink with mildew present; missing showerhead in hallway bathroom; missing toilet seats in master and basement bathrooms; water service was off during inspection preventing full plumbing testing; water heater is a GE 40-gallon natural gas unit manufactured in 2010.
- Roof3-tab shingle roof estimated 10-15 years old has missing and damaged shingles needing repair; tree limbs are contacting/hanging over the roof; gutters are clogged with leaves and debris; fascia and edge shingles at rear of home are damaged.
- WindowsOne broken basement window pane was observed and needs to be replaced.

12030 Lavida Avenue
St. Louis, MO
Whole-home inspection, 2463 Shannonaire Drive, Jennings, MO 63136
Greensmith Home Inspection LLC documented home inspection work at 2463 Shannonaire Drive, Jennings, MO 63136 on August 23, 2023. Missing and non-functional smoke detectors need replacement with operational units.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of a single-family property identified multiple deficiencies across roofing, structure, HVAC, plumbing, electrical, pest, and exterior systems requiring repair, replacement, or further evaluation before closing.
- ElectricalMissing and non-functional smoke detectors need replacement with operational units; busted porch light at rear patio has exposed hot wires; ungrounded two-prong outlets are present throughout the home; exterior electric noted as needing repairs.
- FoundationOne long horizontal crack is present on the north basement wall requiring repair; multiple cracks in the exterior foundation need epoxy injection sealing; signs of previous moisture intrusion with musty smell observed in basement; section of driveway concrete has sunk creating a trip hazard.
- HVACThe Ruud furnace (manufactured 2016, 75,000 BTU) has had its heat exchanger removed and needs it replaced, rendering the HVAC inoperable; the HVAC exhaust duct has been torn loose; thermostat batteries need replacement; Ruud 2-ton condenser (2016) is present.
- PestOlder termite damage is present on wood window shims, overhead garage door trim, and wood landscape timbers; full termite treatment for the home is recommended.
- PlumbingInterior plumbing includes galvanized steel supply lines that need replacement; the water heater exhaust has lost its seal due to the furnace exhaust being ripped away; the 40-gallon Rheem water heater (manufactured 2018) shows signs of rust from previous moisture intrusion.
- RoofThree-tab shingled roof estimated 20 years old is extensively patched with damaged/lifted shingles and needs full replacement; damaged soffit on front corner, tree limbs overhanging roof, and debris-filled/bent gutters also require attention.
- WindowsOne boarded-up window pane needs replacement and four missing or damaged window screens need to be replaced.

2463 Shannonaire Drive
Jennings, Missouri
Whole-home inspection, 2363 Gardner Drive, St. Louis, MO 63136
Greensmith Home Inspection LLC documented home inspection work at 2363 Gardner Drive, St. Louis, MO 63136 on July 26, 2023. Smoke detectors throughout the home are not operational and need replacement.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of a single-family property identified multiple deficiencies across roofing, structure, HVAC, plumbing, electrical, pest, mold, windows, and foundation systems, with no structural deficiencies observed but numerous repair and further-evaluation items noted.
- ElectricalSmoke detectors throughout the home are not operational and need replacement; a missing light fixture with exposed hot wires and a missing outlet cover were observed in the interior; wasp nests are present in the rear exterior electric outlet.
- FoundationBasement foundation walls of cinder block construction have cracks and missing mortar allowing moisture intrusion; replacement of missing mortar and sealing of cracks is recommended.
- HVACSplit system refrigerant lines have been cut and the HVAC furnace coil has been removed from the basement; the digital thermostat is inoperable and would not power up after battery replacement.
- MoldMold on the main-floor living room ceiling indicates a likely plumbing leak in the second-floor bathroom east of the bathtub; plumbing leak repair and mold/mildew removal are recommended.
- PestOlder termite damage is present on wood framing of the walkout basement and on exterior siding; full termite treatment on the property is recommended unless seller proves prior treatment.
- PlumbingRear exterior faucet is not connected to plumbing and needs properly plumbed; water heater unit has been removed and needs replaced; signs of possible plumbing leaks are present under the second-floor bathroom vanity sink.
- RoofMissing roof sheeting over front porch with rotted wood framing, collapsed roof section over walkout basement, lifted shingles needing sealing, soft roof decking, gaps in fascia board, loose aluminum soffit siding, and loose/unleveled gutters with missing splashblocks and debris.
- WindowsDamage observed to window on west side of home requiring repair and caulking, and one broken window pane needs replacement.

2363 Gardner Drive
St. Louis, Missouri
Whole-home inspection, 9938 Duke Drive, St. Louis, MO 63136
Greensmith Home Inspection LLC documented home inspection work at 9938 Duke Drive, St. Louis, MO 63136 on March 10, 2023. Both smoke detectors in bedrooms are inoperable and need to be replaced.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property at 9938 Duke Dr found the home in generally good shape with no structural deficiencies; actionable items include window caulking, soffit/fascia repair, gutter cleaning, inoperable smoke detectors, mold in rear bedroom ceiling, and damage to middle bedroom ceiling.
- ElectricalBoth smoke detectors in bedrooms are inoperable and need to be replaced; 100-amp Eaton service panel in storage room appears functional with satisfactory breakers.
- FoundationSlab-on-grade poured concrete foundation and wood-frame wall structure are both in satisfactory condition with no structural deficiencies observed.
- HVACCentral split system with Ruud forced-air furnace (manufactured 2006) and Goodman 2-ton condenser (manufactured February 2019) both appear functional and satisfactory.
- MoldMold is present in the rear bedroom ceiling; per occupant, owners previously removed more extensive mold but it has returned and needs remediation; a large hole in the soffit at the corresponding exterior is identified as the likely moisture source.
- PlumbingPEX supply piping in satisfactory condition; Kenmore 40-gallon natural gas water heater (manufactured 2003) appears functional with T&P relief valve and discharge pipe present.
- Roof3-tab shingle and roll roofing estimated 5; 10 years old in satisfactory condition; damaged soffit on west side and damaged fascia on south end require repair; gutters need leaves and debris removed.
- WindowsVinyl windows are satisfactory overall but caulking is needed around windows as observed.

9938 Duke Drive
St. Louis, MO
Whole-home inspection, 9709 Duke Drive, St. Louis, MO 63136
Greensmith Home Inspection LLC documented home inspection work at 9709 Duke Drive, St. Louis, MO 63136 on March 10, 2023. Smoke detectors are missing throughout the home and need to be installed.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of 9709 Duke Dr, St Louis, MO 63136 identified no structural deficiencies but noted multiple items requiring attention including pest damage, HVAC servicing, missing smoke detectors, roof maintenance, and various exterior and interior repairs.
- ElectricalSmoke detectors are missing throughout the home and need to be installed; 100-amp Square D service panel with breakers is satisfactory.
- FoundationSlab-on-grade poured concrete foundation and wood-frame wall structure are satisfactory with no structural deficiencies observed.
- HVACHVAC system (Comfortmaker furnace estimated 20 years old, Goodman condenser manufactured 2013) is functional but dirty and needs to be cleaned and serviced by a licensed HVAC technician.
- PestOlder termite damage observed on wood fence and landscape timbers (not on structure); treatment recommended every 3; 5 years for termites and wood-destroying insects unless seller proves prior treatment.
- PlumbingCopper supply pipes are satisfactory; State natural gas water heater (manufactured 2018, 40-gallon) is functional; tub surround tile in Bathroom #1 needs caulking and/or replacement of damaged tile.
- Roof3-tab shingle roof estimated 15 years old is satisfactory; tree limbs overhanging roof should be cut back, debris removed, loose gutter on west side needs securing, and detached downspout on front corner needs reinstallation.
- WindowsAluminum windows are generally satisfactory but caulking around windows is needed where deteriorated.

9709 Duke Drive
St. Louis, MO
Whole-home inspection, 949 Clearfield Drive, Ferguson, MO 63135
Greensmith Home Inspection LLC documented home inspection work at 949 Clearfield Drive, Ferguson, MO 63135 on March 10, 2023. 100-amp Square D service panel with breakers in satisfactory condition.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of 949 Clearfield Dr found the home in generally good shape with no structural deficiencies; notable issues include damaged front porch railing, rear fence destroyed by neighbor's tree, vegetation contacting structure, inoperative dishwasher, and missing kitchen exhaust fan over gas range.
- Electrical100-amp Square D service panel with breakers in satisfactory condition; smoke detectors are 9-volt battery type only.
- FoundationSmall crack observed in poured concrete foundation at front corner of home; urethane caulk repair recommended; soft spot also noted in kitchen floor next to rear exterior door requiring repair.
- HVACCondensation line is disconnected and laying next to the Goodman furnace (2015), causing moisture to run from the furnace when in use; Ruud 3-ton condenser (2016) appears functional.
- PestNo active termite damage or presence observed on the structure, but older termite damage is present on wood landscaping timbers; spraying for termites/wood-destroying insects every 3; 5 years is recommended.
- PlumbingRuud water heater manufactured 2002 appears functional with 40-gallon natural gas capacity and T&P relief valve present; copper supply pipes and sump pump are satisfactory.
- Roof3-tab shingle roof estimated 25 years old with heavy hail damage and replacement suggested in the near future; guttering on rear half of house has been pulled down and needs reset; ceiling stains in rear bedroom directly below satellite dishes indicate possible roof leak requiring repair.

949 Clearfield Drive
Ferguson, Missouri
Whole-home inspection, 334 Caithness Road, St. Louis, MO 63137
Greensmith Home Inspection LLC documented home inspection work at 334 Caithness Road, St. Louis, MO 63137 on March 10, 2023.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of 334 Caithness Rd identified 16 items needing attention including electrical deficiencies, a basement wall crack, aging HVAC, and deferred maintenance items; no structural deficiencies were observed.
- ElectricalAll electric outlets in the living room are inoperable and need repair/replacement, the kitchen GFI outlet is burned out and needs replacement, smoke detectors are missing throughout the home, and tree limbs are pushing on overhead power lines requiring Ameren to address.
- FoundationOne horizontal crack approximately 8 feet long on the west basement wall needs to be repaired with epoxy injection; no moisture intrusion was observed.
- HVACGoodman central split system furnace and air conditioner (both manufactured 2005) appear to be performing but need to be cleaned and serviced by a licensed HVAC technician.
- PestOlder termite damage is present on wood landscape timbers; no damage or active presence was observed to the structure, but treatment is recommended every 3 to 5 years for termites/wood destroying insects.
- PlumbingTub faucet handle is disconnected and needs to be reattached; water heater (State, electric, 40 gal, manufactured 2019) is satisfactory with supply pipes (copper) and waste pipes (cast iron) in satisfactory condition.
- RoofThree-tab shingled roof is estimated 10 years old and appears to be performing with patching done; missing downspout on front corner, wood fascia needs scraping and painting with openings sealed, and tree limbs should be cut back from hanging over the roof.
334 Caithness Road
St. Louis, MO
Greensmith Home Inspection LLC is a home inspection company based in St. Louis, Missouri. As of November 22, 2026, Fresh House holds 110 documented inspection records for Greensmith Home Inspection LLC at 106 properties in 23 municipalities, dated January 2022 to November 2026. The records contain findings from inspection reports. Original inspection reports are not shown publicly on this profile. This page carries no ratings, no reviews and no paid placement.
What the Fresh House records show
| Finding | Count | Sentence |
|---|---|---|
| HVAC findings | 100 records | 100 published records for Greensmith Home Inspection LLC include HVAC findings. |
| Electrical findings | 99 records | 99 published records for Greensmith Home Inspection LLC include Electrical findings. |
| Home Inspection findings | 99 records | 99 published records for Greensmith Home Inspection LLC include Home Inspection findings. |
| Plumbing findings | 98 records | 98 published records for Greensmith Home Inspection LLC include Plumbing findings. |
| Foundation findings | 95 records | 95 published records for Greensmith Home Inspection LLC include Foundation findings. |
| Roof findings | 94 records | 94 published records for Greensmith Home Inspection LLC include Roof findings. |
| Pest findings | 88 records | 88 published records for Greensmith Home Inspection LLC include Pest findings. |
| Windows findings | 76 records | 76 published records for Greensmith Home Inspection LLC include Windows findings. |
| Sewer findings | 45 records | 45 published records for Greensmith Home Inspection LLC include Sewer findings. |
| Radon findings | 14 records | 14 published records for Greensmith Home Inspection LLC include Radon findings. |
| Mold findings | 13 records | 13 published records for Greensmith Home Inspection LLC include Mold findings. |
Topic counts describe records, not unique inspections, test results or the number of homes with a defect. A record may cover several topics. Record dates cover January 2022 to November 2026. 18 records use the upload date because no source-document date is available.
Where Greensmith Home Inspection has documented work
Documented record locations on Fresh House (as of November 22, 2026): 23 municipalities.
- St. Louis, MO (49 records)
- Florissant, MO (17)
- St. Peters, MO (7)
- Jennings, MO (4)
- O'Fallon, MO (4)
- Wentzville, MO (4)
- Ballwin, MO (2)
- Berkeley, MO (2)
- Chesterfield, MO (2)
- Fenton, MO (2)
- Ferguson, MO (2)
- Hazelwood, MO (2)
- St. Charles, MO (2)
- University City, MO (2)
- Arnold, MO (1)
- Creve Coeur, MO (1)
- De Soto, MO (1)
- Imperial, MO (1)
- Lake St. Louis, MO (1)
- Maryland Heights, MO (1)
- Normandy, MO (1)
- Troy, MO (1)
- Wright City, MO (1)
Quick answers about Greensmith Home Inspection
Who is Greensmith Home Inspection LLC?
Greensmith Home Inspection LLC is a home inspection company based in St. Louis, Missouri. As of November 22, 2026, Fresh House holds 110 documented records for Greensmith Home Inspection LLC at 106 properties, dated January 2022 to November 2026. 18 records use the upload date because no source-document date is available.
What inspection topics appear in Greensmith Home Inspection LLC records?
Published records for Greensmith Home Inspection LLC include HVAC, Electrical, Home Inspection, Plumbing, Foundation, Roof, Pest, Windows, Sewer, Radon and Mold findings. These are documented record topics, not a promise that every record covers every topic.
Do Greensmith Home Inspection LLC records include sewer findings?
Yes. Greensmith Home Inspection LLC has 45 published records with Sewer findings. This counts records mentioning the topic, not individual tests or positive results.
Do Greensmith Home Inspection LLC records include radon findings?
Yes. Greensmith Home Inspection LLC has 14 published records with Radon findings. This counts records mentioning the topic, not individual tests or positive results.
Do Greensmith Home Inspection LLC records include pest findings?
Yes. Greensmith Home Inspection LLC has 88 published records with Pest findings. This counts records mentioning the topic, not individual tests or positive results.
Are Greensmith Home Inspection LLC's original inspection reports published?
No. Original inspection reports are not shown publicly. This page shows the findings documented in those records.
Where does Greensmith Home Inspection LLC have documented records?
Fresh House records place its documented work in 23 municipalities, most often St. Louis (49 records), Florissant (17), St. Peters (7), Jennings (4) and O'Fallon (4). These are record locations, not a statement of the business's service area.
Which other professionals have records at the same properties as Greensmith Home Inspection LLC?
16 properties with Greensmith Home Inspection LLC records also carry records from Arch Air Services (HVAC), 10 from Drain Clean USA, LLC (plumbing), five from ASSURED HEATING AND COOLING (HVAC) and two from Electrical & Data Service Co. (electrical).
How to read this evidence
Fresh House publishes extracted findings from eligible source records and does not republish the original inspection reports on this profile.
Inspection observations do not establish that repairs or treatment were completed.
Services listed on the business profile are business statements, not proof that each service appears in the record history.
Record topics describe eligible records and do not establish current offerings, frequency, or credentials.
Documented property locations are not a claim about current service coverage.
18 records use a labeled upload-date fallback because no source-document date is available.
No license, certification, or other credential is inferred unless a verified issuer and identifier are present.
Services and record topics
HVAC findings
100 published records for Greensmith Home Inspection LLC include HVAC findings.
Electrical findings
99 published records for Greensmith Home Inspection LLC include Electrical findings.
Home Inspection findings
99 published records for Greensmith Home Inspection LLC include Home Inspection findings.
Plumbing findings
98 published records for Greensmith Home Inspection LLC include Plumbing findings.
Foundation findings
95 published records for Greensmith Home Inspection LLC include Foundation findings.
Roof findings
94 published records for Greensmith Home Inspection LLC include Roof findings.
Pest findings
88 published records for Greensmith Home Inspection LLC include Pest findings.
Windows findings
76 published records for Greensmith Home Inspection LLC include Windows findings.
Sewer findings
45 published records for Greensmith Home Inspection LLC include Sewer findings.
Radon findings
14 published records for Greensmith Home Inspection LLC include Radon findings.
Mold findings
13 published records for Greensmith Home Inspection LLC include Mold findings.
Stated coverage
The business profile states coverage as: St. Louis City, St. Louis County, Saint Charles County, Warren County, Jefferson County. This profile-stated coverage remains separate from the documented property locations above.
Contact Greensmith Home Inspection LLC
Home inspectorProfessionals documented at the same properties
Greensmith Home Inspection LLC records share properties with four other professionals on Fresh House. Each has a Fresh House profile showing its full documented work history.
- Arch Air Services, HVAC
16 shared properties · freshhouse.co/professional/arch-air-services
- Drain Clean USA, LLC, plumbing
10 shared properties · freshhouse.co/professional/drain-and-plumbing-service
- ASSURED HEATING AND COOLING, HVAC
5 shared properties · freshhouse.co/professional/assured-heating-and-cooling
- Electrical & Data Service Co., electrical
2 shared properties · freshhouse.co/professional/electrical-data-service-co
Inspections, repairs, photos, document what you know about a property.