Full service & record summaryPROPERTY RECORDS
What this professional has documented.
Structured findings below are extracted from the documented professional records shown on this page.
20 property records shown.
Sewer scope and pest inspection, 2468 Hartland Avenue, St. Louis, MO 63114
Greensmith Home Inspection LLC performed a sewer lateral inspection at 2468 Hartland Avenue, St. Louis, MO 63114. The sewer lateral inspection found lines open and flowing with no damages or obstructions observed.
Some source files are restricted or not yet available; only cleared records are shown.
- SewerSewer lateral inspection found lines open and flowing with no damages or obstructions observed.
- Pestno treatment recommended

2468 Hartland Avenue
St. Louis, Missouri
Whole-home inspection, 1840 Saint Anthony Lane, Florissant, MO 63033
Greensmith Home Inspection LLC documented home inspection work at 1840 Saint Anthony Lane, Florissant, MO 63033 on September 8, 2026. Many homeowners insurance companies will not insure homes with these panels.
Some source files are restricted or not yet available; only cleared records are shown.
- Electricalmany homeowners insurance companies will not insure homes with these panels
- FoundationPoured concrete basement foundation is in satisfactory condition with no structural issues, no moisture detected, and no deficiencies observed in basement walls; perimeter insulation is absent and adding insulation is suggested.
- Plumbingthe laundry sink bib faucet is leaking and needs repair the master bathroom vanity sink drains extremely slowly and likely needs the line cleared
- RoofArchitectural shingle roof estimated at 5 years old is installed correctly and in satisfactory condition; tree limbs overhanging the roof should be cut back, and squirrels are climbing onto the roof and chewing the lattice on the rear deck.
- SewerThe main cast-iron sewer stack is rusted and needs repair with rusted sections replaced; the sewer lateral line requires cabling and clearing to remove a complete root blockage along with scaling and barnacles on the pipe interior.
- SewerTree roots have formed a total blockage at the transition from cast-iron to clay pipe in the sewer lateral; recommendation to cable/clear the lines to remove roots, scaling, and buildup.
- Pestno treatment recommended
1840 Saint Anthony Lane
Florissant, Missouri
Pest inspection, 5837 Oak Forest Lane, St. Louis, MO 63128
Greensmith Home Inspection LLC documented home inspection work at 5837 Oak Forest Lane, St. Louis, MO 63128. Visible evidence of wood destroying insects found: older termite damage on railroad ties in landscaping.
Some source files are restricted or not yet available; only cleared records are shown.
- PestVisible evidence of wood destroying insects found: older termite damage on railroad ties in landscaping; borate-based spray treatment recommended for the affected area.

5837 Oak Forest Lane
St. Louis, Missouri
Whole-home inspection, 41 Old Yorktown Court, Wentzville, MO 63385
Greensmith Home Inspection LLC documented home inspection work at 41 Old Yorktown Court, Wentzville, MO 63385. GFCI outlet protection is not present in the laundry room and must be installed.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of a single-family property found the home in generally great condition with no structural issues; four deficiencies were identified across plumbing, foundation, and electrical systems.
- ElectricalGFCI outlet protection is not present in the laundry room and must be installed.
- FoundationCarbon fiber and epoxy repairs are present on basement walls and appear professionally made and effective; common hairline cracks also observed but not large enough to require repair, and no moisture intrusion was detected.
- HVACdigital thermostat in hallway is satisfactory
- Plumbinggas inspection found aluminum exhaust pipe on water heater must be replaced with galvanized pipe, and a cracked section of pipe on the gas furnace in the basement also requires replacement
- RoofGable roof with 3-year-old architectural shingles inspected by drone; condition is satisfactory with proper installation; flashings, gutters, soffit, fascia, and ventilation all satisfactory.
- HVACGas appliance inspection found insufficient combustion air for furnace and water heater, non-compliant aluminum flue requiring replacement with galvanized, cracked/corroded swivel T, gas meter within 36 inches of electrical service (safety hazard), unsecured thermal expansion tank, unmarked copper gas lines, and condenser with rusty capacitor and improperly attached wire conduit; furnace combustion analyzer test passed with no heat exchanger crack detected.
- SewerSewer lateral is open and flowing with no damages and no obstructions observed; line is comprised of PVC from the basement stack to the city sewer tie-in.
- Pestno action or treatment recommended

41 Old Yorktown Court
Wentzville, Missouri
Sewer scope and pest inspection and radon test, 15 Dorchester Court, St. Peters, MO 63376
Greensmith Home Inspection LLC documented home inspection work at 15 Dorchester Court, St. Peters, MO 63376. No damages or obstructions were observed to the sewer lateral line.
Some source files are restricted or not yet available; only cleared records are shown.
- SewerNo damages or obstructions were observed to the sewer lateral line; lines are open and flowing properly, constructed of PVC from the basement sewer stack to the city sewer tie-in.
- PestPeters, MO found no visible evidence of wood destroying insects no treatment recommended
- RadonRadon test conducted in basement over 53 hours (Sept 2; 4, 2026) using RadStar RS300 monitor; average reading was 0.5 pCi/L, maximum 1.5 pCi/L, minimum 0.1 pCi/L.

15 Dorchester Court
St. Peters, Missouri
Whole-home inspection, 2125 Crane Drive, Florissant, MO 63031
Greensmith Home Inspection LLC documented home inspection work at 2125 Crane Drive, Florissant, MO 63031. Breakers satisfactory 2-prong ungrounded outlets present throughout interior.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of 2125 Crane Dr, Florissant, MO found the home in generally great condition with no structural issues; deficiencies noted include a failed furnace CO test, wasp nests in garage, tree limbs contacting structure, and two windows with broken seals.
- Electricalbreakers satisfactory 2-prong ungrounded outlets present throughout interior
- FoundationPoured concrete basement foundation in satisfactory condition; no moisture detected; basement walls, floor, and stairs show no deficiencies.
- HVACGas furnace combustion analyzer test failed; CO levels do not meet industry standards qualified HVAC contractor recommended to evaluate, make necessary adjustments, and retest
- PestWasp nests are present inside the attached garage and need to be removed; no termite presence or damage observed to the structure.
- PlumbingCopper supply and cast iron waste pipes in satisfactory condition
- RoofArchitectural shingle roof estimated 1; 5 years old and in satisfactory condition; tree limbs are contacting the structure and need to be cut back.
- WindowsTwo rear-facing windows have broken seals and need to be repaired or replaced.
- HVACGas appliance inspection found furnace combustion analyzer test failed with elevated CO levels (GAI-1); single-wall flue requires 6-inch clearance and double-wall flue requires 1-inch clearance to combustibles (GAI-7, GAI-8); condenser dirty with system pressure outside expected range; water heater and stove passed; gas lines hold pressure.
- Pestno action or treatment recommended

2125 Crane Drive
Florissant, Missouri
Whole-home inspection, 3511 Pennsylvania Avenue, St. Louis, MO 63118
Greensmith Home Inspection LLC documented home inspection work at 3511 Pennsylvania Avenue, St. Louis, MO 63118. Smoke detectors in Unit #1 are inoperable — functioning smoke detectors must be installed throughout both units.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of a 2-family property found no structural deficiencies; 7 deficiencies noted across exterior, electrical, plumbing, and interior systems, with inoperable smoke detectors as the primary life-safety concern.
- ElectricalSmoke detectors in Unit #1 are inoperable; functioning smoke detectors must be installed throughout both units; both units have 200-amp Square D breaker panels located in the basement.
- FoundationBasement foundation in acceptable condition with no moisture intrusion observed; brick masonry exterior has minor damage at top corner requiring repair and tuck-pointing; rear balcony and patio are structurally sound but need painting and have loose bannisters to secure.
- HVACBoth units have 2009 Goodman electric forced-air furnaces (appearing functional) and 2024 Goodman 2.5-ton split-system AC condensers; Unit #1 uses flexible ducting, Unit #2 uses metal ducting.
- PlumbingPVC supply and waste pipes in both units; Unit #1 water heater is completely wrapped and condition is unknown; seller information recommended; Unit #2 has a 40-gallon electric water heater appearing functional; loose kitchen faucet in Unit #2 requires securing.
- RoofRoll roofing estimated 5 years old and performing properly; metal gutters present; inspected via drone.
- WindowsWood, vinyl, and aluminum windows present; caulking around windows and doors recommended as needed.
- Pestno action or treatment recommended

3511 Pennsylvania Avenue
St. Louis, Missouri
Whole-home inspection, 2125 Crane Drive, Florissant, MO 63031
Greensmith Home Inspection LLC documented home inspection work at 2125 Crane Drive, Florissant, MO 63031 on September 1, 2026. Breakers satisfactory 2-prong ungrounded outlets present throughout interior.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of 2125 Crane Dr, Florissant, MO found the home in generally great condition with no structural issues; deficiencies noted include a failed furnace CO test, wasp nests in garage, tree limbs contacting structure, and two windows with broken seals.
- Electricalbreakers satisfactory 2-prong ungrounded outlets present throughout interior
- FoundationPoured concrete basement foundation in satisfactory condition; no moisture detected; basement walls, floor, and stairs show no deficiencies.
- HVACGas furnace combustion analyzer test failed; CO levels do not meet industry standards qualified HVAC contractor recommended to evaluate, make necessary adjustments, and retest
- PestWasp nests are present inside the attached garage and need to be removed; no termite presence or damage observed to the structure.
- PlumbingCopper supply and cast iron waste pipes in satisfactory condition
- RoofArchitectural shingle roof estimated 1; 5 years old and in satisfactory condition; tree limbs are contacting the structure and need to be cut back.
- WindowsTwo rear-facing windows have broken seals and need to be repaired or replaced.
- SewerSewer lateral inspection found the lateral open and flowing with no damages or obstructions observed.

2125 Crane Drive
Florissant, Missouri
Radon test, 2021 Twin Fawns Court, St. Peters, MO 63376
Greensmith Home Inspection LLC documented home inspection work at 2021 Twin Fawns Court, St. Peters, MO 63376. Average result was 0.4 pCi/L, maximum 1.3 pCi/L, minimum 0.0 pCi/L — well below the EPA action level of 4.0 pCi/L.
Some source files are restricted or not yet available; only cleared records are shown.
- Radonaverage result was 0.4 pCi/L, maximum 1.3 pCi/L, minimum 0.0 pCi/L; well below the EPA action level of 4.0 pCi/L

2021 Twin Fawns Court
St. Peters, Missouri
Pest inspection, 2021 Twin Fawns Court, St. Peters, MO 63376
Greensmith Home Inspection LLC documented home inspection work at 2021 Twin Fawns Court, St. Peters, MO 63376. Older termite damage observed on wood fence posts.
Some source files are restricted or not yet available; only cleared records are shown.
- PestOlder termite damage observed on wood fence posts; no active termite activity found on the structure; borate-based treatment recommended for the affected area.

2021 Twin Fawns Court
St. Peters, Missouri
Whole-home inspection, 3943 Greer Avenue, St. Louis, MO 63107
Greensmith Home Inspection LLC documented home inspection work at 3943 Greer Avenue, St. Louis, MO 63107 on August 26, 2026.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of a 2-family property identified multiple deficiencies including aged HVAC systems, a missing chimney cap, dry-rotted deck planks, window gaps, missing smoke detectors in Unit 2, and a non-functional bathroom electrical fixture and GFCI outlet; roof and water heaters are in satisfactory condition.
- ElectricalUnit 2 (first-floor) has no smoke detectors installed and requires them throughout Unit 2 bathroom light fixture and GFCI outlet are non-functional following a reported popping sound, with all panel breakers confirmed on
- FoundationStone basement foundation shows common spalling with no moisture intrusion observed; inspector recommends scraping affected sections and applying Drylok or similar product to prevent future moisture intrusion.
- HVACannual cleaning and servicing recommended no exhaust ventilation is present above gas ranges in either kitchen unit
- Plumbingboth water heaters are performing properly
- RoofArchitectural shingles are satisfactory and estimated 5; 7 years old; masonry chimney on the north side is missing its cap and requires replacement; metal gutters present.
- WindowsCaulking needed around doors and windows throughout; the dining room window in the first-floor unit has a large gap that the occupant has filled with rags to block outside air.
- SewerSewer lateral lines are open and flowing with no damages or obstructions observed; lines are constructed of PVC from the main stack through to the city sewer tie-in.
- Pestno action or treatment recommended

3943 Greer Avenue
St. Louis, Missouri
Whole-home inspection, 1289 Summergate Parkway, St. Peters, MO 63303
Greensmith Home Inspection LLC documented home inspection work at 1289 Summergate Parkway, St. Peters, MO 63303. GFCI outlet at front porch is outdated and won't reset and needs replacement.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of townhouse/villa found the home in generally good condition with no structural issues; four deficiencies identified across electrical, roofing, foundation, and interior systems.
- ElectricalGFCI outlet at front porch is outdated and won't reset and needs replacement; rear deck GFCI outlet is functional but busted weatherproof cover needs replacement; 200-amp Square D panel with breakers rated satisfactory.
- FoundationCrack in basement corner has previously allowed moisture intrusion; epoxy injection recommended to seal crack; common hairline cracks also present but too small to repair; no moisture detected at time of inspection.
- HVACannual cleaning and servicing by a licensed HVAC contractor recommended
- PlumbingState 40-gallon natural gas water heater (manufactured 2008) functioning properly; copper supply pipes, PVC waste pipes, and sealed-crock sump pump all rated satisfactory.
- RoofArchitectural shingle roof estimated 10 years old is satisfactory; a small section of missing gutter guard over the front porch needs replacement; gutters, downspouts, flashings, soffit, and fascia otherwise satisfactory.
- WindowsMinor damage around basement window from a previous leak requires repair; no moisture was detected in the area at time of inspection.
- Pestno action or treatment recommended

1289 Summergate Parkway
St. Peters, Missouri
Whole-home inspection, 1224 Kilgore Drive, St. Louis, MO 63137
Greensmith Home Inspection LLC documented home inspection work at 1224 Kilgore Drive, St. Louis, MO 63137 on August 21, 2026. Basement smoke detector battery is almost completely dead and replacement is recommended remaining smoke detectors functioned properly 2-prong ungrounded outlets present throughout interior.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property found generally good condition with no structural issues; four deficiencies noted; low attic insulation, unsecured basement handrail, nearly dead smoke detector battery, and unplugged refrigerator.
- ElectricalBasement smoke detector battery is almost completely dead and replacement is recommended remaining smoke detectors functioned properly 2-prong ungrounded outlets present throughout interior
- FoundationBasement handrail is not secure and needs a middle bracket installed; attic insulation is low (should rise above rafters) and additional blown-in fiberglass insulation is recommended; perimeter insulation not visible; no moisture detected and poured concrete foundation is satisfactory.
- HVACdigital thermostat and metal ducting satisfactory
- Plumbingcopper and PEX supply pipes and PVC waste pipes satisfactory no sump pump present main water shutoff located in basement
- RoofArchitectural shingle gable roof estimated 10; 12 years old is installed correctly and in satisfactory condition; flashings, gutters, soffit, fascia, and ventilation all satisfactory; no skylights present.
- WindowsVinyl exterior windows and double-hung/fixed interior windows are in satisfactory condition.
- Pestno action or treatment recommended

1224 Kilgore Drive
St. Louis, Missouri
Whole-home inspection, 4974 Brookton Way, St. Louis, MO 63128
Greensmith Home Inspection LLC documented home inspection work at 4974 Brookton Way, St. Louis, MO 63128 on August 19, 2026. One family room outlet has hot and neutral wires reversed and needs correction.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property found home in generally good condition with no structural issues; deficiencies noted across site, roofing, electrical, HVAC, plumbing, sewer, foundation, windows, and interior systems.
- ElectricalOne family room outlet has hot and neutral wires reversed and needs correction; GFCI outlets are missing at basement laundry and basement bar (within 6 ft of sink); smoke detector absent near basement gas appliances; master bathroom heat lamp switch is faulty and cannot be turned off.
- FoundationPreviously repaired exterior foundation cracks are aged and dried and need to be resealed with fresh epoxy; large cracks present in concrete garage floor require repair; repaired basement wall crack appears functional with no moisture intrusion observed.
- Plumbingrear exterior faucet is non-functional and loose from the wall and needs repair
- RoofArchitectural shingle roof estimated 1 year old and installed correctly; one plastic vent pipe flashing is improper and needs correction.
- SewerNo damage observed to sewer lateral lines, but scaling has built up in the cast-iron section reducing pipe diameter and causing water to hold; hydroflushing recommended to remove scaling and restore flow.
- WindowsThe window over the kitchen sink has a disconnected crank handle that needs to be reset, preventing the window from closing fully.
- SewerNo structural damage observed to sewer lateral lines; however, scaling has built up and reduced the diameter of the line, and part of the cast-iron section is holding water due to scaling; hydroflushing recommended to remove scaling and restore flow.
- Pestno action or treatment recommended

4974 Brookton Way
St. Louis, Missouri
Whole-home inspection, 1212 Grenshaw Drive, St. Louis, MO 63137
Greensmith Home Inspection LLC documented home inspection work at 1212 Grenshaw Drive, St. Louis, MO 63137 on August 19, 2026. Cutler Hammer 100-amp panel is functional.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property identified multiple deficiencies including end-of-life HVAC, sewer lateral root intrusion, damaged gutter, failed bathroom GFCI, reversed laundry GFCI wiring, loose basement handrail, and missing smoke detectors; no structural issues found.
- ElectricalCutler Hammer 100-amp panel is functional; smoke detectors are missing throughout the home, bathroom GFCI outlet is older and will not trip (needs replacement), and laundry GFCI outlet has hot and ground wires reversed; 2-prong ungrounded outlets are present.
- FoundationPoured concrete basement foundation is satisfactory with no moisture detected and no deficiencies observed in basement walls; loose handrail on basement stairs needs to be secured.
- HVACvegetation is crowding the AC condenser
- Plumbingcopper supply pipes and PVC waste pipes are satisfactory
- RoofArchitectural shingles estimated 5-10 years old and performing properly; a fallen tree limb damaged the gutter which needs replacement, and the front corner downspout needs reset as it is dumping rain wash onto the roof.
- SewerNo damage found to sewer lateral lines, but heavy tree root intrusion and sludge are present; hydroflushing recommended to maintain proper flow and prevent backups.
- SewerSewer lateral inspection found no structural damage to the lateral lines, but heavy tree root intrusion and sludge are present; hydroflushing is recommended to maintain proper flow and prevent backups.
- Pestno action or treatment recommended
1212 Grenshaw Drive
St. Louis, Missouri
Whole-home inspection, 2248 Kerwin Drive, St. Louis, MO 63136
Greensmith Home Inspection LLC documented home inspection work at 2248 Kerwin Drive, St. Louis, MO 63136. Deficiencies include tree limbs pushing on overhead power lines (power company contact recommended), missing smoke detectors throughout home, and one inoperable hallway outlet.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property found home in generally good condition with no structural issues; deficiencies noted include aged HVAC (2000/2002), sewer lateral sludge and root intrusion, loose soffit, tree limbs on power lines, missing smoke detectors, attic fan needing replacement, minor ceiling damage in rear bedroom, and one inoperable hallway outlet.
- Electricaldeficiencies include tree limbs pushing on overhead power lines (power company contact recommended), missing smoke detectors throughout home, and one inoperable hallway outlet
- FoundationPoured concrete basement foundation is satisfactory with no structural issues, no moisture detected, and previous basement wall repairs appeared effective.
- HVACattic fan is operable but too slow to lift slats and likely needs replacement
- Plumbingsewer lateral has sludge buildup in cast-iron portion and tree root intrusion in clay portion, with sludge accumulation damming the line and holding water; hydroflushing recommended
- RoofShingled roof was recently replaced and installed correctly with new architectural shingles; deficiency noted: loose soffit on rear corner of home needs to be secured.
- WindowsVinyl exterior windows and double-hung/fixed interior windows are in satisfactory condition.
- Pestno action or treatment recommended

2248 Kerwin Drive
St. Louis, Missouri
Pest inspection, 2128 Lexa Drive, Jennings, MO 63136
Greensmith Home Inspection LLC documented home inspection work at 2128 Lexa Drive, Jennings, MO 63136. Visual inspection of SFR and detached garage found no visible evidence of wood destroying insects.
Some source files are restricted or not yet available; only cleared records are shown.
- PestVisual inspection of SFR and detached garage found no visible evidence of wood destroying insects; no treatment recommended.

2128 Lexa Drive
Jennings, Missouri
Whole-home inspection, 214 Sugar Lake Drive, St. Peters, MO 63376
Greensmith Home Inspection LLC documented home inspection work at 214 Sugar Lake Drive, St. Peters, MO 63376 on August 14, 2026. Challenger electric panel (125-amp service) has critical safety flaws — breakers frequently fail to trip during overloads or short circuits — replacement recommended.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of condo at 214 Sugar Lake Dr found the property in great condition with no structural issues; deficiencies noted in electrical (Challenger panel, open breaker slot, deck GFCI outlet) and HVAC (annual service needed).
- ElectricalChallenger electric panel (125-amp service) has critical safety flaws; breakers frequently fail to trip during overloads or short circuits; replacement recommended; open breaker slot needs a blank cover installed; rear deck outlet requires replacement with a GFCI-protected outlet.
- FoundationSlab-on-grade poured concrete foundation and wood-frame wall structure both observed in satisfactory condition with no deficiencies noted.
- HVACAmerican Standard central split system (2.5-ton condenser, manufactured 2017) is performing properly but requires annual cleaning and servicing by a licensed HVAC contractor.
- PlumbingAO Smith 28-gallon electric water heater (manufactured 2017) appears functional; copper supply pipes in satisfactory condition; T&P relief valve present with blow-off leg.

214 Sugar Lake Drive
St. Peters, Missouri
Whole-home inspection, 2054 Krause Hill Place, Florissant, MO 63031
Greensmith Home Inspection LLC documented home inspection work at 2054 Krause Hill Place, Florissant, MO 63031 on August 13, 2026.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property found home in generally good condition with no structural issues; deficiencies noted across electrical, HVAC, plumbing, windows, foundation, and pest categories.
- Electrical200-amp Crouse-Hinds panel (aged but performing) with multiple missing GFCI outlets (kitchen, laundry, rear exterior), one inoperable patio outlet, one basement outlet with hot and neutral wires reversed, and two-prong ungrounded outlets present throughout.
- FoundationUnfinished basement floor has cracks that should be sealed with epoxy; exterior foundation crack should be sealed with urethane caulk; no moisture intrusion observed in basement.
- HVACGoodman central split system (furnace and 3-ton condenser) manufactured in 2011 is functioning properly but requires annual cleaning and servicing; vegetation crowding the AC condenser must be removed.
- PestOlder termite damage observed on a small section of wooden fence in the backyard; no active termite activity found on the rest of the structure; treatment or fence removal recommended.
- PlumbingBasement laundry sink drains directly into open floor drain (needs proper P-trap and connection to sewer stack); Rheem 40-gallon natural gas water heater (manufactured 2017) functioning properly; main water shutoff needs corrosion removed.
- RoofArchitectural shingle roof estimated 2-5 years old, installed correctly and in satisfactory condition; gable design with metal flashings, aluminum soffit/fascia, and metal gutters all satisfactory.
- WindowsTwo windows (one in living room, one in master bedroom) have broken seals and need replacement; bedroom window plastic grille is broken and taped; basement window trim cut too close preventing windows from opening; a safety concern.
- SewerSewer lateral lines are open and flowing with no obstructions and no damages observed; lateral lines are PVC from the main stack to the city tie-in.
- PestVisual inspection found older termite damage on the wood fence; no live insects observed; recommendation to spray the affected area with a borate-based solution or remove the damaged fence.
- Radonaverage result was 3.0 pCi/L over 91 hourly intervals, with a minimum of 1.3 pCi/L and maximum of 4.9 pCi/L
2054 Krause Hill Place
Florissant, Missouri
Whole-home inspection, 1363 Kroeger Drive, St. Louis, MO 63135
Greensmith Home Inspection LLC documented home inspection work at 1363 Kroeger Drive, St. Louis, MO 63135 on August 13, 2026. GFCI-protected outlets are absent in the bathroom, kitchen, and basement laundry.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property identified multiple deficiencies including an end-of-life 1974 furnace, sewer line with rootball intrusion and disconnected joint, basement foundation crack with mildew, missing GFCI outlets, 3 broken window panes, and an inoperable exterior faucet; no structural issues noted.
- ElectricalGFCI-protected outlets are absent in the bathroom, kitchen, and basement laundry; one dining-room outlet is inoperable; 2-prong ungrounded outlets are present throughout; 100-amp Murray panel with breakers appears functional.
- FoundationCrack in basement foundation wall has allowed moisture intrusion resulting in mildew growth; a leaking basement window has rusted the frame and damaged the window seal, contributing to moisture intrusion.
- HVACLennox gas furnace manufactured in 1974 is at end of expected lifespan; Aire Flo 2.5-ton AC condenser manufactured in 2011 was operational but failed to cool the home and requires cleaning and servicing.
- PlumbingRear exterior faucet is loose and inoperable; bathtub stuck on shower mode with loose faucet handles; 2008 General Electric 40-gallon natural gas water heater is functional but gas supply shut-off valve has been pressed into the unit rendering it unusable.
- RoofArchitectural shingle roof estimated at 10 years old is installed correctly and in satisfactory condition; gutters contain leaves and need cleaning; tree limbs overhang the roof and should be cut back.
- SewerExcessive scaling in cast-iron sewer line with apparent collapsed section, large tree root intrusion forming a rootball, and a disconnected joint at the PVC-to-clay pipe transition separated roughly 2 inches, preventing camera access to the sewer main; hydroflushing recommended.
- WindowsThree broken window panes require replacement (2 bedroom windows, 1 basement window); many interior windows are painted shut and need to be opened for safety; bathroom window has been taped shut.
- SewerSewer lateral inspection found excessive scaling in cast-iron section, a possible collapsed section or heavy scaling buildup, tree root intrusion forming a large rootball, an offset at the PVC-to-clay pipe transition, and a disconnected joint separated roughly 2" that prevented camera access to the sewer main; hydroflushing recommended.
- PestVisual inspection of SFR/Attached Garage at 1363 Kroeger Drive found no visible evidence of wood destroying insects; no action or treatment recommended.

1363 Kroeger Drive
St. Louis, Missouri
Greensmith Home Inspection LLC is a home inspection company based in St. Louis, Missouri. As of November 22, 2026, Fresh House holds 110 documented inspection records for Greensmith Home Inspection LLC at 106 properties in 23 municipalities, dated January 2022 to November 2026. The records contain findings from inspection reports. Original inspection reports are not shown publicly on this profile. This page carries no ratings, no reviews and no paid placement.
What the Fresh House records show
| Finding | Count | Sentence |
|---|---|---|
| HVAC findings | 100 records | 100 published records for Greensmith Home Inspection LLC include HVAC findings. |
| Electrical findings | 99 records | 99 published records for Greensmith Home Inspection LLC include Electrical findings. |
| Home Inspection findings | 99 records | 99 published records for Greensmith Home Inspection LLC include Home Inspection findings. |
| Plumbing findings | 98 records | 98 published records for Greensmith Home Inspection LLC include Plumbing findings. |
| Foundation findings | 95 records | 95 published records for Greensmith Home Inspection LLC include Foundation findings. |
| Roof findings | 94 records | 94 published records for Greensmith Home Inspection LLC include Roof findings. |
| Pest findings | 88 records | 88 published records for Greensmith Home Inspection LLC include Pest findings. |
| Windows findings | 76 records | 76 published records for Greensmith Home Inspection LLC include Windows findings. |
| Sewer findings | 45 records | 45 published records for Greensmith Home Inspection LLC include Sewer findings. |
| Radon findings | 14 records | 14 published records for Greensmith Home Inspection LLC include Radon findings. |
| Mold findings | 13 records | 13 published records for Greensmith Home Inspection LLC include Mold findings. |
Topic counts describe records, not unique inspections, test results or the number of homes with a defect. A record may cover several topics. Record dates cover January 2022 to November 2026. 18 records use the upload date because no source-document date is available.
Where Greensmith Home Inspection has documented work
Documented record locations on Fresh House (as of November 22, 2026): 23 municipalities.
- St. Louis, MO (49 records)
- Florissant, MO (17)
- St. Peters, MO (7)
- Jennings, MO (4)
- O'Fallon, MO (4)
- Wentzville, MO (4)
- Ballwin, MO (2)
- Berkeley, MO (2)
- Chesterfield, MO (2)
- Fenton, MO (2)
- Ferguson, MO (2)
- Hazelwood, MO (2)
- St. Charles, MO (2)
- University City, MO (2)
- Arnold, MO (1)
- Creve Coeur, MO (1)
- De Soto, MO (1)
- Imperial, MO (1)
- Lake St. Louis, MO (1)
- Maryland Heights, MO (1)
- Normandy, MO (1)
- Troy, MO (1)
- Wright City, MO (1)
Quick answers about Greensmith Home Inspection
Who is Greensmith Home Inspection LLC?
Greensmith Home Inspection LLC is a home inspection company based in St. Louis, Missouri. As of November 22, 2026, Fresh House holds 110 documented records for Greensmith Home Inspection LLC at 106 properties, dated January 2022 to November 2026. 18 records use the upload date because no source-document date is available.
What inspection topics appear in Greensmith Home Inspection LLC records?
Published records for Greensmith Home Inspection LLC include HVAC, Electrical, Home Inspection, Plumbing, Foundation, Roof, Pest, Windows, Sewer, Radon and Mold findings. These are documented record topics, not a promise that every record covers every topic.
Do Greensmith Home Inspection LLC records include sewer findings?
Yes. Greensmith Home Inspection LLC has 45 published records with Sewer findings. This counts records mentioning the topic, not individual tests or positive results.
Do Greensmith Home Inspection LLC records include radon findings?
Yes. Greensmith Home Inspection LLC has 14 published records with Radon findings. This counts records mentioning the topic, not individual tests or positive results.
Do Greensmith Home Inspection LLC records include pest findings?
Yes. Greensmith Home Inspection LLC has 88 published records with Pest findings. This counts records mentioning the topic, not individual tests or positive results.
Are Greensmith Home Inspection LLC's original inspection reports published?
No. Original inspection reports are not shown publicly. This page shows the findings documented in those records.
Where does Greensmith Home Inspection LLC have documented records?
Fresh House records place its documented work in 23 municipalities, most often St. Louis (49 records), Florissant (17), St. Peters (7), Jennings (4) and O'Fallon (4). These are record locations, not a statement of the business's service area.
Which other professionals have records at the same properties as Greensmith Home Inspection LLC?
16 properties with Greensmith Home Inspection LLC records also carry records from Arch Air Services (HVAC), 10 from Drain Clean USA, LLC (plumbing), five from ASSURED HEATING AND COOLING (HVAC) and two from Electrical & Data Service Co. (electrical).
How to read this evidence
Fresh House publishes extracted findings from eligible source records and does not republish the original inspection reports on this profile.
Inspection observations do not establish that repairs or treatment were completed.
Services listed on the business profile are business statements, not proof that each service appears in the record history.
Record topics describe eligible records and do not establish current offerings, frequency, or credentials.
Documented property locations are not a claim about current service coverage.
18 records use a labeled upload-date fallback because no source-document date is available.
No license, certification, or other credential is inferred unless a verified issuer and identifier are present.
Services and record topics
HVAC findings
100 published records for Greensmith Home Inspection LLC include HVAC findings.
Electrical findings
99 published records for Greensmith Home Inspection LLC include Electrical findings.
Home Inspection findings
99 published records for Greensmith Home Inspection LLC include Home Inspection findings.
Plumbing findings
98 published records for Greensmith Home Inspection LLC include Plumbing findings.
Foundation findings
95 published records for Greensmith Home Inspection LLC include Foundation findings.
Roof findings
94 published records for Greensmith Home Inspection LLC include Roof findings.
Pest findings
88 published records for Greensmith Home Inspection LLC include Pest findings.
Windows findings
76 published records for Greensmith Home Inspection LLC include Windows findings.
Sewer findings
45 published records for Greensmith Home Inspection LLC include Sewer findings.
Radon findings
14 published records for Greensmith Home Inspection LLC include Radon findings.
Mold findings
13 published records for Greensmith Home Inspection LLC include Mold findings.
Stated coverage
The business profile states coverage as: St. Louis City, St. Louis County, Saint Charles County, Warren County, Jefferson County. This profile-stated coverage remains separate from the documented property locations above.
Contact Greensmith Home Inspection LLC
Home inspectorProfessionals documented at the same properties
Greensmith Home Inspection LLC records share properties with four other professionals on Fresh House. Each has a Fresh House profile showing its full documented work history.
- Arch Air Services, HVAC
16 shared properties · freshhouse.co/professional/arch-air-services
- Drain Clean USA, LLC, plumbing
10 shared properties · freshhouse.co/professional/drain-and-plumbing-service
- ASSURED HEATING AND COOLING, HVAC
5 shared properties · freshhouse.co/professional/assured-heating-and-cooling
- Electrical & Data Service Co., electrical
2 shared properties · freshhouse.co/professional/electrical-data-service-co
Inspections, repairs, photos, document what you know about a property.