Pest inspection, 9505 Margo Ann Lane, St. Louis, MO 63134
Greensmith Home Inspection LLC performed a gas appliance inspection at 9505 Margo Ann Lane, St. Louis, MO 63134. Gas pressure test and combustion analyzer test both passed.
Some source files are restricted or not yet available; only cleared records are shown.
- HVACGas appliance inspection found flue venting too close to combustible materials (single-wall requires 6" clearance, double-wall requires 1" clearance), missing TPRV discharge pipe on water heater, condenser not level, and rusty capacitor on addition condenser; gas pressure test and combustion analyzer test both passed; no major concerns noted.
- PestVisual inspection of 9505 Margo Ann Lane found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or reinfesting wood boring beetles); no treatment recommended.

9505 Margo Ann Lane
St. Louis, Missouri
Pest inspection, 87 Cimarron Summit Way, Wentzville, MO 63385
Greensmith Home Inspection LLC documented home inspection work at 87 Cimarron Summit Way, Wentzville, MO 63385. Visual inspection of 87 Cimarron Summit Way found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or wood boring beetles).
Some source files are restricted or not yet available; only cleared records are shown.
- PestVisual inspection of 87 Cimarron Summit Way found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or wood boring beetles); no treatment recommended.

87 Cimarron Summit Way
Wentzville, Missouri
Whole-home inspection, 3243 Delor Street, St. Louis, MO 63111
Greensmith Home Inspection LLC documented home inspection work at 3243 Delor Street, St. Louis, MO 63111 on August 7, 2026. Both Unit #1 and Unit #2 have Eaton 100-amp service panels with breakers located in the basement.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of two-family building at 3243 Delor St found the property in generally good condition with no structural issues; six deficiencies identified across roofing, HVAC, plumbing, and mold.
- ElectricalBoth Unit #1 and Unit #2 have Eaton 100-amp service panels with breakers located in the basement; smoke detectors present in both units.
- FoundationBasement foundation of stone construction with wood-framed floors and masonry wall structure; no structural issues detected.
- HVACUnit #1 has a 1998 York gas furnace (92,000 BTU) that has hit the end of expected life; Unit #2 has a 2019 Comfortmaker gas furnace (66,000 BTU), but the central AC is inoperable per the occupant; 3 AC condensers on roof (2 older, 1 newer), and the occupant relies on window units; missing dryer exhaust vents also noted in Unit #2 laundry.
- MoldMildew has formed inside the bathroom sink cabinet in Unit #2 as a result of the ongoing plumbing leak under the sink.
- PlumbingUnit #2 bathroom sink has an active plumbing leak that has persisted for months despite a report to property management; both basement laundry hookups drain into the laundry sink (improperly plumbed) and the laundry sink faucet is inoperable; both units have 2018 Rheem 40-gallon electric water heaters.
- RoofTPO roofing estimated 1-2 years old and in great shape; deficiency noted; soffit damage on the front corner of the building requires repair.
- SewerNo damages or obstructions were observed to the sewer lateral lines.
- SewerSewer lateral inspection found lines open and flowing with no visible damage; lines are PVC all the way to the city's main connection.

3243 Delor Street
St. Louis, Missouri
Whole-home inspection, 9835 Portage Drive, St. Louis, MO 63136
Greensmith Home Inspection LLC documented home inspection work at 9835 Portage Drive, St. Louis, MO 63136 on August 6, 2026. Sewer lateral lines are open and flowing.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property found the home generally in good condition with no structural issues; deficiencies noted include a cracked cast-iron sewer stack, inoperable sump pump with sparking outlet, cracked roof vent stack, and failed tub diverter valve.
- SewerSewer lateral lines are open and flowing; light scaling is present on the cast-iron portion but not enough to require cabling; no issues flagged.
- PestVisual WDI inspection of SFR/Attached Carport at 9835 Portage Drive found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or reinfesting wood boring beetles); no treatment recommended.
- Electrical100-amp Eaton service panel in basement is functional; 2-prong ungrounded outlets are present throughout; a functioning smoke detector should be installed in the basement near gas appliances.
- FoundationPoured concrete basement foundation is in satisfactory condition with no moisture detected and no deficiencies observed in basement walls or stairs; perimeter insulation is absent and adding insulation is suggested.
- HVACGoodman central split system (manufactured 2015, 2.5-ton condenser) is functioning correctly but requires annual cleaning and servicing as it is over 10 years old.
- PlumbingA crack in the main sewer stack's cast-iron section is causing water to leak onto the basement floor; the sump pump is inoperable with a full sump well and a sparking outlet (both need replacement); the water heater expansion tank has a rusted fitting needing replacement; and the tub diverter valve has failed, requiring tub faucet replacement.
- RoofOne metal roof exhaust vent stack is cracked, has been taped, and has lifted flashing; needs replacement; tree limbs are contacting the structure and should be cut back.

9835 Portage Drive
St. Louis, Missouri
Whole-home inspection, 4065 Schiller Place, St. Louis, MO 63116
Greensmith Home Inspection LLC documented home inspection work at 4065 Schiller Place, St. Louis, MO 63116 on August 5, 2026. Visual inspection of SFR at 4065 Schiller Place found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or wood boring beetles).
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection at 4065 Schiller Pl identified multiple deficiencies including a safety-hazard electrical system, full HVAC replacement needed, corroded plumbing supply lines, basement wall cracks, and window defects; no structural issues found.
- PestVisual inspection of SFR at 4065 Schiller Place found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or wood boring beetles); no treatment recommended.
- ElectricalFederal Pacific fuse box (last inspected 1977) requires update; knob-and-tube wiring still present throughout but could not be tested due to no power; 100-amp service; smoke detectors missing throughout home including near basement gas appliances.
- FoundationLarge cracks in basement walls require sealing with epoxy injections to prevent moisture intrusion; exterior basement finished wall cracks also noted; no moisture detected at time of inspection.
- HVACRPJ gas furnace estimated 40 years old is heavily rusted and requires replacement; AC condenser has been removed and is not present; full HVAC system replacement recommended.
- PlumbingSmall section of water supply lines is galvanized steel and heavily corroded/rusted, requiring replacement; Reliance 40-gallon natural gas water heater (manufactured 2014) is functional but missing the TPR valve discharge pipe, which must be replaced.
- RoofArchitectural shingle roof estimated 2-5 years old and in satisfactory condition; loose gutter downspout and fascia panel at rear patio need securing; missing soffit panels need replacement.
- WindowsRear-facing second-floor window is out of frame and needs to be reset; three missing window panes at rear of home require replacement; rear patio door is missing and must be replaced.

4065 Schiller Place
St. Louis, Missouri
Whole-home inspection, 3541 Oregon Avenue, St. Louis, MO 63118
Greensmith Home Inspection LLC performed a sewer lateral scope in each of 2 basement sewer stacks at 3541 Oregon Avenue, St. Louis, MO 63118 on August 5, 2026. All lines are open and flowing with no damages or obstructions observed.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of a 4-unit brick building found good overall condition with no structural issues; deficiencies include an active plumbing leak in Unit #1N, reverse-slope drain plumbing in three kitchens, loose tub faucets in Units #2N and #2S, a damaged North basement door, a cracked South basement wall, and window deficiencies in Unit #1S.
- SewerSewer lateral scope performed in each of 2 basement sewer stacks; all lines are open and flowing with no damages or obstructions observed; most of the line is PVC.
- PestWood Destroying Insect inspection of 4-family complex at 3541 Oregon Avenue found no visible evidence of wood destroying insects; no action or treatment recommended.
- ElectricalEach of the four units has a Square D 100-amp service panel located in the basement with breaker-type overcurrent devices; outlets tested satisfactory in all units; one inoperable smoke detector noted in the North basement (Unit #2N).
- FoundationStone basement foundation with unfinished floors; basement stairs and walls rated satisfactory; one long vertical crack in the South basement wall needs to be sealed to prevent potential water intrusion; North basement door is damaged and has come loose from its frame and needs replacement.
- HVACThree units (1N, 1S, 2S) have Ameristar gas furnaces manufactured in 2006; Unit #2N has a Guardian gas furnace manufactured in 2019; all four units have 2021 Guardian 2-ton split-system AC condensers; all mechanicals appear to be working properly.
- PlumbingActive plumbing leak discovered behind Unit #1N washer/dryer combo causing water to spill to basement floor; under-sink drain plumbing has a reverse slope in Units #1S, #2N, and #2S kitchens; loose tub faucets in Units #2N and #2S; toilet water supply shut off in Unit #2S; all four 2006-manufactured water heaters (two 40-gal Hotpoint, two 30-gal GE) appear functional.
- RoofTPO roofing inspected via drone is rated satisfactory and estimated 1; 3 years old; metal gutters present; no deficiencies noted.
- WindowsA front-facing window in Unit #1S needs the locking mechanism replaced; several windows in Unit #1S are hard to open and need window balances adjusted.

3541 Oregon Avenue
St. Louis, Missouri
Whole-home inspection, 7541 Norwalk Lane, St. Louis, MO 63121
Greensmith Home Inspection LLC documented home inspection work at 7541 Norwalk Lane, St. Louis, MO 63121 on August 4, 2026. Sewer lateral line is completely blocked with debris and tree roots.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property identified multiple deficiencies including a blocked sewer lateral, broken exterior GFCI outlet, inoperable kitchen exhaust fan, broken thermostat, disconnected fireplace flue handle, cracked basement windows, and older termite damage; roof (1-3 years old) and structure were satisfactory with no structural issues noted.
- SewerSewer lateral line is completely blocked with debris and tree roots; two sections of the cast-iron pipe are cracked allowing root intrusion; hydroflushing and sleeve repairs at both cracks are recommended.
- PestVisible evidence of wood destroying insects found: older termite damage present on wood exterior door trim; no live insects observed; treatment with borate-based solution recommended.
- ElectricalExterior GFCI outlet at front corner is broken, won't reset, and is loose from the wall; two outlets in the rear add-on room have reversed hot/neutral wiring and a loose mounting; laundry area lacks GFCI-protected outlet; kitchen exhaust fan is inoperable with no power.
- FoundationPoured concrete foundation is in satisfactory condition; common corner cracks observed and inspector recommends sealing with heavy-duty epoxy paste; no moisture detected in basement.
- HVACThermostat battery door is broken and keeps popping open, canceling the HVAC system and requiring repair or replacement; Goodman central split system (2.5-ton A/C, mfgd 2019) and Goodman forced-air gas furnace are otherwise functioning satisfactorily.
- PestOlder termite damage is visible on the exterior door trim with no other signs of active infestation found; treatment with a borate-based solution (e.g., Bora-Care) is recommended unless seller can prove prior treatment.
- PlumbingState brand 40-gallon natural gas water heater (manufactured 2019) is functioning properly; copper supply pipes are satisfactory; sump pump not present.
- RoofArchitectural shingle roof estimated 1-3 years old is installed correctly and in satisfactory condition; gable-end ventilation, metal vent stacks, gutters, and downspouts are all satisfactory.
- SewerThe sewer lateral line is completely blocked with debris and tree roots; two sections of the cast-iron portion are cracked, allowing root intrusion; lateral requires hydroflushing and sleeve repairs at the two cracks.
- WindowsFront living room window will not lock; lock mechanism is loose and needs securing; two basement glassblock windows have small cracks and need repair or replacement; fireplace flue handle in living room is disconnected and will not open the flue.

7541 Norwalk Lane
St. Louis, Missouri
Whole-home inspection, 5563 Winchelsea Drive, Normandy, MO 63121
Greensmith Home Inspection LLC documented home inspection work at 5563 Winchelsea Drive, Normandy, MO 63121 on August 4, 2026. No structural damage observed to sewer lateral lines.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property identified multiple deficiencies including inoperative AC unit, full sewer blockage with tree root intrusion, unsecured attic ladder, missing carport storm door, and bathroom window that won't lock; home otherwise appears in good condition with no structural issues.
- SewerNo structural damage observed to sewer lateral lines; however, a full blockage is present at the city main tie-in, excessive tree root intrusion found in the clay section, and scaling/buildup in the cast-iron section; hydroflushing recommended, and a Fireball bottle in the laundry drain needs removal.
- PestVisual inspection of 5563 Winchelsea Drive found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or reinfesting wood boring beetles); no treatment recommended.
- Electrical100-amp overhead service with Cutler Hammer panel in utility room is functional; 2-prong ungrounded outlets are present throughout; smoke detectors tested satisfactory.
- FoundationSlab-on-grade poured concrete foundation is in satisfactory condition with no structural issues observed; wood frame wall structure satisfactory; attic ladder is not secure and needs to be stabilized; attic insulation (fiberglass batts) is low and should be added for improved efficiency.
- HVACInternational Comfort gas furnace (manufactured 2002) is satisfactory but over 10 years old and should be serviced yearly; Coleman 2-ton AC condenser (manufactured 2021) failed to operate during inspection and requires servicing.
- PlumbingCopper supply pipes satisfactory; Hotpoint electric 40-gallon water heater (manufactured 2007) is functional but aged; a Fireball bottle was thrown down the laundry drain and needs to be removed; waste pipe materials are PVC, cast iron, and clay.
- RoofArchitectural shingle roof estimated 1-3 years old is installed correctly and in satisfactory condition; ventilation, flashings, soffit, fascia, and gutters all satisfactory.
- SewerFull blockage present at the city main tie-in with excessive tree root intrusion in the clay section and scaling/buildup in the cast-iron section of the sewer lateral line; hydroflushing recommended for proper flow and to prevent backups.
- WindowsBathroom window is older and won't lock and needs to be adjusted; caulking of window interiors is recommended as needed.

5563 Winchelsea Drive
Normandy, Missouri
Whole-home inspection, 1203 Orchard Lakes Drive, St. Louis, MO 63146
Greensmith Home Inspection LLC documented home inspection work at 1203 Orchard Lakes Drive, St. Louis, MO 63146 on July 31, 2026. Visible older termite damage observed on rear wood deck.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection at 1203 Orchard Lakes Dr identified 9 deficiencies across site, plumbing, electrical, and roofing systems; home is in generally good condition with no structural issues and a recently replaced roof.
- PestVisible older termite damage observed on rear wood deck; treatment recommended; spray with borate-based solution and remove affected wood.
- ElectricalGFCI outlets are missing at the front porch, hallway bathroom, kitchen, and laundry area; smoke detectors are missing throughout the home; 2-prong ungrounded outlets are present; 100-amp Siemens panel noted as newer and functional.
- FoundationPoured concrete foundation is satisfactory with no moisture detected; rear walkway and patio have sunk and slanted downward and need to be jacked back to level; significant wood rot on rear deck; replacement of rotted planks or entire deck is advised.
- HVACEmerald forced-air gas furnace and 3-ton Emerald split-system A/C condenser (both manufactured 2025) are functioning correctly; digital thermostat in hallway is satisfactory.
- PestOlder termite damage observed on rear deck railings; treatment with a borate-based solution (such as Bora-Care) is recommended unless seller can prove prior treatment.
- PlumbingAn access hole cut into the cast-iron sewer stack was not properly capped and the pipe appears to have been leaking; master bathroom vanity sink faucets are very loose and need securing; Whirlpool 50-gallon natural gas water heater (manufactured 2014) is functioning properly.
- RoofArchitectural shingle roof was recently replaced and installed correctly (condition: satisfactory); tree limbs are touching the structure and should be trimmed.
1203 Orchard Lakes Drive
St. Louis, Missouri
Whole-home inspection, 811 Russell Boulevard, St. Louis, MO 63104
Greensmith Home Inspection LLC performed a sewer lateral video scope was at 811 Russell Boulevard, St. Louis, MO 63104 on July 30, 2026. No damages or blockages were observed, lines are PVC all the way through and are open and flowing.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of multi-family property found the home in generally good condition with no structural issues; deficiencies noted across HVAC, plumbing, electrical, foundation, and interior systems.
- SewerSewer lateral video scope was performed; no damages or blockages were observed, lines are PVC all the way through and are open and flowing.
- PestVisual WDI inspection of duplex found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or wood boring beetles); no treatment recommended.
- ElectricalTree limbs are pushing on overhead power lines; contact Ameren to trim; smoke detectors are missing throughout the home; GFCI outlet absent at second-floor unit laundry; two Siemens 100-amp panels appear functional.
- FoundationBasement is slightly damp due to dried and cracked mortar in the stone foundation; replace cracked mortar and apply Drylok-type waterproofer; basement perimeter insulation is hanging loose and needs reset.
- HVACSecond-floor York (2017) HVAC system was inoperable from the thermostat with all breakers on; needs serviced, cleaned, and loose power switch secured; filter inaccessible due to tight door; basement Trane (2016) forced-air furnace satisfactory; Trane XR 2-ton condenser (2017) and Emerson 2.5-ton condenser (2020) present.
- PlumbingBasement Water Heater #1 (GE, 2011, 40 gal natural gas) requires a TPR blowoff leg installed to code; second-floor Water Heater #2 (Rheem, 1984, 40 gal natural gas) is nearing end of expected lifespan and needs replacement; soft spot present in third-floor bathroom floor between toilet and tub.
- RoofArchitectural shingle and roll roofing estimated 5; 7 years old in satisfactory condition; masonry chimney, skylights, metal flashings, soffit, fascia, and gutters all satisfactory; no roof ventilation present.
- WindowsInterior windows (double hung, single hung, fixed) are screwed shut and could not be tested for operation; exterior windows in satisfactory condition.

811 Russell Boulevard
St. Louis, Missouri
Whole-home inspection, 30 Graeler Drive, St. Louis, MO 63146
Greensmith Home Inspection LLC documented home inspection work at 30 Graeler Drive, St. Louis, MO 63146 on July 29, 2026. Average result was 5.1 pCi/L, with a minimum of 0.6 pCi/L and a maximum of 12.1 pCi/L over the 47-hour test period.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of 30 Graeler Drive found the property in generally good condition with no structural issues; deficiencies noted across site, roofing, electrical, plumbing, pest, and windows systems.
- RadonRadon test conducted July 29. average result was 5.1 pCi/L, with a minimum of 0.6 pCi/L and a maximum of 12.1 pCi/L over the 47-hour test period
- SewerSewer lateral inspection found tree roots intruding into one small section of cast-iron pipe indicating a crack, with heavy scaling also present; inspector recommends hydroflushing and re-cameraing the lines, with cabling/clearing and root foam as a potential remediation option.
- PestVisible evidence of wood destroying insects found: older termite damage on wood trim around door and on wood fence; borate-based solution treatment recommended; no live insects observed.
- Electricalexposed wood from previously removed meter needs covering. rear patio GFCI outlet won't reset and remains hot after tripping. second exterior outlet needs GFCI replacement. laundry room lacks GFCI outlet. 2-prong ungrounded outlets present throughout interior
- HVACLennox 2.5-ton AC condenser (manufactured 2007) operates properly but needs annual cleaning and servicing due to age; Goodman electric furnace (manufactured 2026) is performing properly.
- PestOlder termite damage present on wood trim around the garage door and on the wood fence; replacement of damaged wood and borate-based treatment (Bora-Care) recommended.
- PlumbingTree roots have intruded into one section of cast-iron waste pipe indicating a crack, with heavy scaling present; hydroflush and re-camera recommended; Bradford White 50-gallon gas water heater (manufactured 2002) is functional but nearing end of expected lifespan.
- RoofSquirrels have chewed the flashing on one roof vent pipe almost completely; vent pipe flashing requires replacement; architectural shingles estimated 7; 10 years old and otherwise satisfactory.
- WindowsFour windows and the rear patio door have broken seals and need repair or replacement; one broken rear-facing window pane also requires replacement.

30 Graeler Drive
St. Louis, Missouri
Whole-home inspection, 10333 Castle Drive, St. Louis, MO 63136
Greensmith Home Inspection LLC documented home inspection work at 10333 Castle Drive, St. Louis, MO 63136 on July 29, 2026. No damages observed to the sewer lateral lines.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of 10333 Castle Drive found extensive deficiencies including stripped HVAC and plumbing systems, a rusted electrical panel, termite damage, mold, and a 15-year-old roof with improperly overlaid shingles; no structural deficiencies were observed.
- SewerNo damages observed to the sewer lateral lines; however, heavy scaling in the cast-iron section has reduced the pipe diameter to the point where the inspector could not make the final turn towards the city main; lines need to be cabled/cleared.
- PestVisible evidence of wood destroying insects observed: termite damage present around wood window frames; borate-based solution treatment recommended.
- ElectricalCutler Hammer electric panel is older, has rusted through, and needs replacement; panel wiring appears mostly intact but could not be tested due to no power; tree limbs are pushing on overhead power lines and require utility company trimming; smoke detectors are non-functional.
- FoundationBasement is very damp with moisture originating from unsealed wall cracks; epoxy injections recommended to seal cracks; perimeter insulation is absent.
- HVACGas furnace and AC condenser have been removed and ductwork destroyed; entire HVAC system needs replacement; exhaust duct also needs replacement.
- MoldMold and mildew are present on interior walls and ceilings, likely resulting from basement moisture infiltrating through unsealed wall cracks.
- PestOlder termite damage observed around window frames; replacement of damaged wood and treatment with a borate-based solution (Bora-Care) recommended unless seller proves prior treatment.
- PlumbingAll plumbing supply lines have been removed and home needs to be re-plumbed with modern materials; 2006 Craftsman 40-gallon gas water heater has been stripped for parts and needs replacement; exterior faucet supply lines have been cut and are disconnected.
- Roof15-year-old 3-tab shingle roof shows signs of wear; newer shingles were incorrectly nailed on top of old shingles and need removal with damaged shingles replaced; gutters are pulled away from the home and need reset or replacement; wood soffit is aged and damaged.
- WindowsFour windows have broken seals and one window pane is cracked; all five panes need replacement, and missing exterior siding should be replaced as needed.

10333 Castle Drive
St. Louis, Missouri
Whole-home inspection, 6904 Dunleer, St. Louis, MO 63130
Greensmith Home Inspection LLC documented home inspection work at 6904 Dunleer, St. Louis, MO 63130 on July 28, 2026. Sewer lateral scope found a collapsed line at the cast-iron to clay pipe joint leaving the home, with soil filling the pipe requiring hydroflushing.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of a vacant, unoccupied single-family property identified numerous deficiencies across all systems including electrical, HVAC, plumbing, roof, foundation, and interior; no structural issues identified but many repairs needed.
- SewerSewer lateral scope found a collapsed line at the cast-iron to clay pipe joint leaving the home, with soil filling the pipe requiring hydroflushing; additionally, the main sewer stack has a large hole in the cast-iron and needs repair or replacement.
- Pestno action or treatment recommended
- ElectricalElectric panel (Square D, 100-amp) has been ripped from the wall and most wiring removed; home needs complete re-wiring; vegetation is pushing on overhead power lines; smoke detectors are missing throughout.
- FoundationOne large crack in the rear basement wall is causing moisture intrusion; front walkway is sunk and severely sloped and needs re-pouring; no structural issues identified overall.
- HVAC1984 Emerson gas furnace has been stripped for parts and AC condenser has been totally removed; full HVAC system replacement needed; thermostat replacement also suggested.
- MoldMoisture and mildew present in the basement, originating from the large rear wall crack and ill-fitted basement windows.
- PlumbingCopper supply lines are cut and heavily corroded requiring full re-plumb; large hole present in cast iron main sewer stack needs repair or replacement; 1997 Richmond 40-gal gas water heater shows heavy rust and needs replacing; bathroom sink plumbing lines removed; bathroom and kitchen subfloors heavily damaged and need replacement.
- RoofMinor repairs needed on 10-year-old 3-tab shingled roof: small hole needs filling and gathered shingles need correction; two damaged areas present in living room ceiling likely related to roof condition.
- WindowsBroken window panes in three windows and missing glass panes in both front and rear storm doors need replacement; leaky window has caused damaged walls in bedroom requiring repair.

6904 Dunleer
St. Louis, Missouri
Whole-home inspection, 4615 Newport Avenue, St. Louis, MO 63116
Greensmith Home Inspection LLC performed a sewer lateral video scope at 4615 Newport Avenue, St. Louis, MO 63116 on July 28, 2026. Compacted grease and feces have formed a full blockage 6' below the main stack access — lines need hydroflushed to remove debris, then re-camera'd behind the blockage.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property identified 11 deficiencies across exterior, roofing, structure, electrical, HVAC, plumbing, sewer, windows, and interior systems; no structural issues found.
- SewerSewer lateral video scope performed; compacted grease and feces have formed a full blockage 6' below the main stack access; lines need hydroflushed to remove debris, then re-camera'd behind the blockage.
- PestWood Destroying Insect inspection of SFR at 4615 Newport Avenue, St. Louis, MO 63116: no visible evidence of wood destroying insects observed; no action or treatment recommended.
- Electrical200-amp Square D service panel in basement appears functional; smoke detectors are broken/missing and functional units need to be installed throughout the home.
- FoundationStone basement walls have worn mortar that needs sealing to prevent moisture intrusion; moisture condition is damp and Drylok or similar coating is recommended.
- HVACPayne central split system (2-ton A/C and forced-air furnace, manufactured 2022) appears functional; HVAC filter is missing and needs replacement.
- PlumbingRheem 40-gallon electric water heater (manufactured 2023) could not be tested due to winterization; missing tub faucet in main-floor bathroom needs replacement; PEX supply pipes satisfactory.
- RoofArchitectural shingle roof estimated 10 years old is satisfactory with patching present; missing aluminum fascia sections need replacement.
- SewerSewer lateral video scope revealed a complete blockage of grease and fecal matter that requires hydroflushing before the remainder of the sewer line can be inspected.
- WindowsTwo broken window panes identified; one in the basement and one in the attached rear room; both need replacement.

4615 Newport Avenue
St. Louis, Missouri
Whole-home inspection, 357 Fork Drive, St. Louis, MO 63137
Greensmith Home Inspection LLC documented home inspection work at 357 Fork Drive, St. Louis, MO 63137 on July 24, 2026. Sewer lateral inspection camera reached only approximately 8 feet before encountering a complete blockage from excessive scaling and/or soil.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of 357 Fork Dr, Saint Louis, MO identified numerous deficiencies including lead supply pipes, a 50-year-old furnace with missing AC condenser, aluminum wiring, basement moisture, fire damage, mildew, and older termite damage; further specialist evaluations strongly recommended before closing.
- SewerSewer lateral inspection camera reached only approximately 8 feet before encountering a complete blockage from excessive scaling and/or soil; soil presence indicates a possible break in the line, and hydroflushing with re-scoping is recommended.
- PestWDI inspection found older termite damage on front landscape timbers; no evidence of live insects or damage elsewhere in the structure; recommendation to remove timbers or treat with a borate-based solution.
- ElectricalMost wiring is older aluminum and will likely need replacement; electric meter box has been cut and needs replaced; 125-amp GE panel in basement; smoke detectors missing or inoperable; no GFCI outlet present in kitchen.
- FoundationBasement moisture condition rated Wet; most moisture is attributed to broken windows and missing mortar in cinderblock walls; walls are in good shape overall but need cleaning and mortar touch-up.
- HVACFedders gas furnace estimated 50 years old is missing parts and needs replacement; AC condenser is missing; HVAC ductwork is older and damaged and needs replacement.
- MoldSigns of mildew present on walls and ceilings throughout the interior, likely attributed to moisture intrusion from broken windows and excessive vegetation; fire damage with charred wood trim also noted in basement stairwell and kitchen area.
- PestOlder termite damage observed on front landscape timbers; treatment recommended unless seller proves prior treatment; inspector suggests removing timbers or applying a borate-based solution such as Bora-Care.
- PlumbingHome was plumbed with lead supply pipes (small amount of PEX has been removed) and needs full replumbing with modern materials; water heater has been removed and needs replacement.
- Roof3-tab shingle roof estimated 5-10 years old is installed correctly but tree limbs dropping onto the roof are causing leaks; gutters are pulling away from the home, missing downspouts need replacement, and gutters are full of debris.
- WindowsMultiple broken and missing windows observed throughout the home; broken windows are a primary source of basement moisture intrusion and interior mildew growth.

357 Fork Drive
St. Louis, Missouri
Whole-home inspection, 1316 Westbrooke Terrace Drive, Ballwin, MO 63021
Greensmith Home Inspection LLC documented home inspection work at 1316 Westbrooke Terrace Drive, Ballwin, MO 63021 on July 22, 2026. Sewer lateral lines are open and flowing.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property identified multiple deficiencies including seized gas shutoff valves, an end-of-life water heater with leaking expansion tank, a rusted AC capacitor, an open neutral outlet, missing/inoperable smoke detectors, a broken kitchen window pane, and a sunken front walkway trip hazard.
- SewerSewer lateral lines are open and flowing; no damages and no blockages observed from the city main tap-in to the main sewer stack in the basement; entire line appears to be ABS.
- PestWood Destroying Insect inspection of SFR/Attached Garage at 1316 Westbrooke Terrace Drive, Ballwin, MO found no visible evidence of wood destroying insects; no action or treatment recommended.
- ElectricalOne living room outlet has an open neutral wire that needs corrected; most smoke detectors are inoperable or missing and functioning smoke detectors need to be installed throughout the home; service panel is Square D 100-amp with breakers, appears functional.
- FoundationA section of the front concrete walkway has sunk, creating a trip hazard; recommendation is to jack up the sunken slab back to level; poured concrete foundation is satisfactory with no structural issues observed.
- HVACGoodman 3.5-ton AC condenser (manufactured 2018) is operating properly but the capacitor has rusted and needs replacement; International Comfort gas furnace (97,000 BTU, manufactured 2020) is performing properly; airflow is uneven in certain rooms suggesting ductwork may need cleaning.
- PlumbingGas water heater (AO Smith, manufactured 2000) has reached end of expected lifespan and the expansion tank exhibits multiple signs of leakage and needs replacement; gas shutoff valves for furnace and water heater are seized shut and need replacement; basement laundry gas line is loose and needs a drip leg installed; leaky bib faucet in basement laundry is dripping onto the floor; hallway bathroom tub faucet, toilet, and cold water vanity faucet have been shut off.
- RoofArchitectural shingle roof estimated 1-2 years old is installed correctly and in satisfactory condition; ventilation, flashings, soffit, fascia, and gutters are satisfactory; loose aluminum soffit over porch needs to be tucked.
- WindowsKitchen sink window has one broken pane and one broken seal; both panes need replacement; minor damage observed to trim of other windows.
- HVACwater heater (2000, 50-gallon) has rust inside and suspected sediment buildup. further evaluation and possible replacement recommended. gas runs use rigid black steel pipe but shut-off valves are not hand-turnable, gas lines need securing and drip legs, though pressure test passed. condenser (2018, 3.5-ton) has fence restricting airflow and rusty capacitor with system pressure outside expected range. fence removal and capacitor replacement recommended. ductwork is rusty, dirty, inadequately sized, not sealed, and has missing/falling hangers

1316 Westbrooke Terrace Drive
Ballwin, Missouri
Whole-home inspection, 5018 Country Valley Drive, Imperial, MO 63052
Greensmith Home Inspection LLC documented home inspection work at 5018 Country Valley Drive, Imperial, MO 63052 on July 21, 2026. Visual WDI inspection of SFR/Attached Garage at 5018 Country Valley Drive, Imperial, MO found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or reinfesting wood boring beetles).
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property identified 6 deficiencies across site, exterior, HVAC, and bathrooms; no structural issues found; roof approximately 1 year old and in satisfactory condition.
- PestVisual WDI inspection of SFR/Attached Garage at 5018 Country Valley Drive, Imperial, MO found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or reinfesting wood boring beetles); no treatment recommended.
- ElectricalEaton service panel (200-amp, newer) located in garage is functional and satisfactory; breaker overcurrent protection satisfactory; smoke detectors (9-volt battery type) tested satisfactory; no defects noted at electric outlets.
- FoundationPoured concrete basement foundation in satisfactory condition; hairline crack in front foundation corner recommended to be sealed with urethane; minor basement wall cracks appear effectively sealed with Drylok-type material; no moisture intrusion observed.
- HVACGoodman central split system (forced air furnace and 2-ton condenser, both manufactured 2007) functions correctly but requires annual cleaning and servicing due to age; system is over 10 years old and a licensed HVAC contractor should be consulted.
- PestNo termite or pest presence or damage observed at the property.
- PlumbingFront exterior faucet is leaking from the top cap with dried/cracked caulk and needs replacement; bathroom vanity faucet screen appears clogged causing low water pressure; bathroom floor and baseboard trim damaged by previous plumbing leaks with cracked mortar on ceramic tile; Rheem 40-gallon natural gas water heater (manufactured 2017) is functioning properly.
- RoofArchitectural shingle roof estimated to be approximately 1 year old is installed correctly and in satisfactory condition; gable-end and ridge vents, metal flashings, aluminum soffit/fascia, and metal gutters all satisfactory.
- WindowsVinyl and steel-framed basement windows are in satisfactory condition; some interior windows are hard to open and inspector recommends cleaning and lubricating window tracks for ease of use.

5018 Country Valley Drive
Imperial, Missouri
Whole-home inspection, 2243 Bolton Street, St. Charles, MO 63301
Greensmith Home Inspection LLC performed a wood destroying insect inspection at 2243 Bolton Street, St. Charles, MO 63301 on July 21, 2026. The wood destroying insect inspection found visible termite damage on wood trim around the garage door.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of single-family property identified multiple deficiencies across site, exterior, electrical, HVAC, plumbing, and interior systems; no structural issues observed.
- PestWood destroying insect inspection found visible termite damage on wood trim around the garage door; borate-based spray treatment recommended.
- ElectricalNewer Siemens 200-amp panel door blocked by plumbing line obstruction; one front bedroom outlet inoperable, one basement outlet has hot and neutral wires reversed; GFCI outlet missing at laundry washing machine circuit.
- FoundationPoured concrete basement foundation is in satisfactory condition; common cracks in corners noted and sealing with heavy-duty epoxy paste is recommended.
- HVACGoodman gas furnace manufactured 2017 is functional; 2-ton Carrier AC condenser manufactured 1998 has hit the end of its expected life and replacement is indicated.
- PestOlder termite damage observed on overhead garage door trim; treatment with borate-based solution (Bora-Care) recommended unless seller proves prior treatment.
- PlumbingPVC cap on main sewer stack has stripped threads and needs replacement; toilet likely has a leaky flange with water dropping to basement floor when flushed; exterior faucet is loose; AO Smith 40-gal natural gas water heater manufactured 2022 is functional.
- RoofArchitectural shingle roof estimated 3-5 years old is installed correctly and in satisfactory condition; one damaged wood fascia board on rear corner needs replacement.
- WindowsBathroom window will not lock; the older locking mechanism needs to be replaced.

2243 Bolton Street
St. Charles, Missouri
Whole-home inspection, 1825 Myers Road, Troy, MO 63379
Greensmith Home Inspection LLC documented home inspection work at 1825 Myers Road, Troy, MO 63379 on July 17, 2026. Visual WDI inspection of SFR and detached garage at 1825 Myers Road, Troy, MO found no visible evidence of wood destroying insects.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of a single-family manufactured home identified multiple deficiencies including a GFCI outlet, window issues, tree limbs on roof, fireplace flue, and furnace needing service; no structural issues found.
- PestVisual WDI inspection of SFR and detached garage at 1825 Myers Road, Troy, MO found no visible evidence of wood destroying insects; no treatment recommended.
- ElectricalRear exterior outlet is functional but requires replacement with a GFCI-protected plug; 200-amp Cutler Hammer service panel in utility room is satisfactory.
- FoundationConcrete block foundation with vinyl vapor barrier and metal panel skirting all in satisfactory condition; no structural issues observed.
- HVACIntertherm electric forced-air furnace estimated 10-15 years old is functional but requires cleaning and servicing; Goodman 3.5-ton AC condenser manufactured 2026 appears functional; wood-burning fireplace flue will not close from the handle and needs repair.
- PestNo termite or pest presence or damage observed at the time of inspection.
- PlumbingRheem 40-gallon electric water heater manufactured 2011 appears functional; PEX supply and PVC waste pipes in satisfactory condition; property served by septic system.
- RoofArchitectural shingle roof estimated 3-5 years old is in satisfactory condition; tree limbs touching the structure should be trimmed; tar/caulk flashings will likely need re-sealing annually.
- WindowsBroken window track near rear deck needs replacement; front windows caulked sloppily and need correction; one kitchen window has a broken seal needing repair or replacement; some windows are difficult to lock and others have loose pile weatherstripping.

1825 Myers Road
Troy, Missouri
Whole-home inspection, 2904 Advance Drive, Florissant, MO 63031
Greensmith Home Inspection LLC performed a sewer lateral video inspection at 2904 Advance Drive, Florissant, MO 63031 on July 16, 2026. The sewer lateral video inspection found no damages or obstructions, however the cast-iron section of line has heavy scaling and needs cabled/cleared to prevent blockages.
Some source files are restricted or not yet available; only cleared records are shown.
- Home InspectionWhole-home inspection of a single-family property found the home in generally good condition with no structural issues; deficiencies noted in HVAC, bathrooms, electrical, and kitchen.
- SewerSewer lateral video inspection found no damages or obstructions, however the cast-iron section of line has heavy scaling and needs cabled/cleared to prevent blockages.
- PestVisual inspection of SFR/Attached Garage found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or reinfesting wood boring beetles); no treatment recommended.
- ElectricalSquare D 100-amp service panel in basement is satisfactory and noted as a newer panel; GFCI outlet in master bathroom will not reset and needs to be replaced.
- FoundationPoured concrete basement foundation is in satisfactory condition with no moisture detected and no deficiencies observed in basement walls or stairs; perimeter insulation is absent and adding more is suggested.
- HVACYork gas furnace (manufactured 1994) is functioning but approaching end of expected life and requires annual cleaning and servicing; Rheem 2.5-ton AC condenser (manufactured 2018) appears functional but also needs cleaning and servicing.
- PlumbingRheem 40-gallon natural gas water heater (manufactured 2023) is functioning properly; hallway bathroom toilet water supply was shut off and requires further evaluation; exterior faucet handle is loose and needs securing; shower walls in hallway bathroom require re-grouting; master bathroom shower floor has a crack that needs repair.
- RoofArchitectural shingle roof (gable design, estimated 2-5 years old) inspected by walking; condition satisfactory with proper ventilation, metal flashings, aluminum soffit/fascia, and metal gutters all in satisfactory condition.
- WindowsVinyl and steel-framed basement windows inspected and found in satisfactory condition; interior double-hung and fixed window types also satisfactory.

2904 Advance Drive
Florissant, Missouri
Greensmith Home Inspection LLC is a home inspection company based in St. Louis, Missouri. As of November 22, 2026, Fresh House holds 110 documented inspection records for Greensmith Home Inspection LLC at 106 properties in 23 municipalities, dated January 2022 to November 2026. The records contain findings from inspection reports. Original inspection reports are not shown publicly on this profile. This page carries no ratings, no reviews and no paid placement.
What the Fresh House records show
| Finding | Count | Sentence |
|---|---|---|
| HVAC findings | 100 records | 100 published records for Greensmith Home Inspection LLC include HVAC findings. |
| Electrical findings | 99 records | 99 published records for Greensmith Home Inspection LLC include Electrical findings. |
| Home Inspection findings | 99 records | 99 published records for Greensmith Home Inspection LLC include Home Inspection findings. |
| Plumbing findings | 98 records | 98 published records for Greensmith Home Inspection LLC include Plumbing findings. |
| Foundation findings | 95 records | 95 published records for Greensmith Home Inspection LLC include Foundation findings. |
| Roof findings | 94 records | 94 published records for Greensmith Home Inspection LLC include Roof findings. |
| Pest findings | 88 records | 88 published records for Greensmith Home Inspection LLC include Pest findings. |
| Windows findings | 76 records | 76 published records for Greensmith Home Inspection LLC include Windows findings. |
| Sewer findings | 45 records | 45 published records for Greensmith Home Inspection LLC include Sewer findings. |
| Radon findings | 14 records | 14 published records for Greensmith Home Inspection LLC include Radon findings. |
| Mold findings | 13 records | 13 published records for Greensmith Home Inspection LLC include Mold findings. |
Topic counts describe records, not unique inspections, test results or the number of homes with a defect. A record may cover several topics. Record dates cover January 2022 to November 2026. 18 records use the upload date because no source-document date is available.
Where Greensmith Home Inspection has documented work
Documented record locations on Fresh House (as of November 22, 2026): 23 municipalities.
- St. Louis, MO (49 records)
- Florissant, MO (17)
- St. Peters, MO (7)
- Jennings, MO (4)
- O'Fallon, MO (4)
- Wentzville, MO (4)
- Ballwin, MO (2)
- Berkeley, MO (2)
- Chesterfield, MO (2)
- Fenton, MO (2)
- Ferguson, MO (2)
- Hazelwood, MO (2)
- St. Charles, MO (2)
- University City, MO (2)
- Arnold, MO (1)
- Creve Coeur, MO (1)
- De Soto, MO (1)
- Imperial, MO (1)
- Lake St. Louis, MO (1)
- Maryland Heights, MO (1)
- Normandy, MO (1)
- Troy, MO (1)
- Wright City, MO (1)
Quick answers about Greensmith Home Inspection
Who is Greensmith Home Inspection LLC?
Greensmith Home Inspection LLC is a home inspection company based in St. Louis, Missouri. As of November 22, 2026, Fresh House holds 110 documented records for Greensmith Home Inspection LLC at 106 properties, dated January 2022 to November 2026. 18 records use the upload date because no source-document date is available.
What inspection topics appear in Greensmith Home Inspection LLC records?
Published records for Greensmith Home Inspection LLC include HVAC, Electrical, Home Inspection, Plumbing, Foundation, Roof, Pest, Windows, Sewer, Radon and Mold findings. These are documented record topics, not a promise that every record covers every topic.
Do Greensmith Home Inspection LLC records include sewer findings?
Yes. Greensmith Home Inspection LLC has 45 published records with Sewer findings. This counts records mentioning the topic, not individual tests or positive results.
Do Greensmith Home Inspection LLC records include radon findings?
Yes. Greensmith Home Inspection LLC has 14 published records with Radon findings. This counts records mentioning the topic, not individual tests or positive results.
Do Greensmith Home Inspection LLC records include pest findings?
Yes. Greensmith Home Inspection LLC has 88 published records with Pest findings. This counts records mentioning the topic, not individual tests or positive results.
Are Greensmith Home Inspection LLC's original inspection reports published?
No. Original inspection reports are not shown publicly. This page shows the findings documented in those records.
Where does Greensmith Home Inspection LLC have documented records?
Fresh House records place its documented work in 23 municipalities, most often St. Louis (49 records), Florissant (17), St. Peters (7), Jennings (4) and O'Fallon (4). These are record locations, not a statement of the business's service area.
Which other professionals have records at the same properties as Greensmith Home Inspection LLC?
16 properties with Greensmith Home Inspection LLC records also carry records from Arch Air Services (HVAC), 10 from Drain Clean USA, LLC (plumbing), five from ASSURED HEATING AND COOLING (HVAC) and two from Electrical & Data Service Co. (electrical).
How to read this evidence
Fresh House publishes extracted findings from eligible source records and does not republish the original inspection reports on this profile.
Inspection observations do not establish that repairs or treatment were completed.
Services listed on the business profile are business statements, not proof that each service appears in the record history.
Record topics describe eligible records and do not establish current offerings, frequency, or credentials.
Documented property locations are not a claim about current service coverage.
18 records use a labeled upload-date fallback because no source-document date is available.
No license, certification, or other credential is inferred unless a verified issuer and identifier are present.
Services and record topics
HVAC findings
100 published records for Greensmith Home Inspection LLC include HVAC findings.
Electrical findings
99 published records for Greensmith Home Inspection LLC include Electrical findings.
Home Inspection findings
99 published records for Greensmith Home Inspection LLC include Home Inspection findings.
Plumbing findings
98 published records for Greensmith Home Inspection LLC include Plumbing findings.
Foundation findings
95 published records for Greensmith Home Inspection LLC include Foundation findings.
Roof findings
94 published records for Greensmith Home Inspection LLC include Roof findings.
Pest findings
88 published records for Greensmith Home Inspection LLC include Pest findings.
Windows findings
76 published records for Greensmith Home Inspection LLC include Windows findings.
Sewer findings
45 published records for Greensmith Home Inspection LLC include Sewer findings.
Radon findings
14 published records for Greensmith Home Inspection LLC include Radon findings.
Mold findings
13 published records for Greensmith Home Inspection LLC include Mold findings.
Stated coverage
The business profile states coverage as: St. Louis City, St. Louis County, Saint Charles County, Warren County, Jefferson County. This profile-stated coverage remains separate from the documented property locations above.
Contact Greensmith Home Inspection LLC
Home inspectorProfessionals documented at the same properties
Greensmith Home Inspection LLC records share properties with four other professionals on Fresh House. Each has a Fresh House profile showing its full documented work history.
- Arch Air Services, HVAC
16 shared properties · freshhouse.co/professional/arch-air-services
- Drain Clean USA, LLC, plumbing
10 shared properties · freshhouse.co/professional/drain-and-plumbing-service
- ASSURED HEATING AND COOLING, HVAC
5 shared properties · freshhouse.co/professional/assured-heating-and-cooling
- Electrical & Data Service Co., electrical
2 shared properties · freshhouse.co/professional/electrical-data-service-co
Inspections, repairs, photos, document what you know about a property.